1. INSTALLATION AND WIRING
10
9. Apply adhesive to the flat washers, spring washers, and hex. nuts.
1.6
Wiring
Wiring considerations
• Turn the power at the switchboard off before beginning the wiring.
•
For DRS12A X-Class and DRS25A X-Class
, the 5 A fuse in the fuse holder (sup-
plied with the cable assembly) must be replaced with the supplied 10 A fuse. Also,
attach the supplied fuse rating label to the fuse holder. For details, see “How to Re-
place the Fuse” (C32-01604).
• The cable assembly and power/LAN cables have connector(s). Do NOT cut the ca-
ble assembly and power/LAN cables even if the cables are run through a radar
mast.
• When you replace the DRS4A/6A/12A/25A with the DRS6A X-Class/DRS12A X-
Class/DRS25A X-Class, the existing cable cannot be used. Use only the cable as-
sembly supplied with this radar sensor
Adhesive
Insulation sheet
Flat washer
Spring washer
Hex. nut
Stud bolt
Detailed view
Power/LAN cable:
Pre-attached to the antenna unit.
Cable assembly