5-1
5.
MAINTENANCE,
TROUBLESHOOTING
5.1
Maintenance
Regular maintenance is essential for good performance. Check the items listed in the
table below at the suggested interval to help keep your equipment in good shape for
years to come.
Item
Check point, action
Check interval
Cable condition
Check that cables are not damaged. Replace if
damaged.
Once a month
Cable connector
Check that the connector of each cable is tightly
fastened and not damaged. Refasten if neces-
sary. Replace if damaged.
Once a month
Ground terminal, ground
wire
Check for corrosion. Clean if necessary. Replace
ground wire if damaged.
Once a month
Power supply voltage
Check voltage. If out of rating correct problem.
Once a month
Cabinet cleanliness
Dust or dirt on the cabinet may be removed with a
dry cloth. Do not use chemical-based cleaners to
clean the cabinet; they can remove markings and
damage the cabinet.
Once a month
Transducer
Marine life on the transducer face will result in a
gradual decrease in sensitivity. Check the trans-
ducer face for cleanliness each time the boat is
removed from the water. Carefully remove any
marine life with a piece of wood or fine-grade
sandpaper.
When the vessel is
removed from the
water.
WARNING
NOTICE
Do not apply paint, anti-corrosive sealant or
contact spray to coating or plastic parts of
the equipment.
Those items contain organic solvents that can
damage coating and plastic parts, especially
plastic connectors.
ELECTRICAL SHOCK HAZARD
Do not open the equipment.
Only qualified personnel are
permitted to work inside the
equipment.
Содержание DFF-3D
Страница 1: ...MULTI BEAM SONAR DFF 3D OPERATOR S MANUAL www furuno com Model ...
Страница 10: ...SYSTEM CONFIGURATION viii This page is intentionally left blank ...
Страница 14: ...1 INSTALLATION 1 4 Unit of measurement Top millimeter Bottom inch ...
Страница 16: ...1 INSTALLATION 1 6 This page is intentionally left blank ...
Страница 36: ...3 INITIAL SETTINGS 3 10 This page is intentionally left blank ...
Страница 54: ...4 OPERATION 4 18 This page is intentionally left blank ...
Страница 68: ...APPENDIX 4 INSTALLATION OF TRANSDUCER TM54 AP 12 This page is intentionally left blank ...
Страница 71: ...D 1 20 Sep 2016 H MAKI 20 Sep 2016 H MAKI 20 Sep 2016 H MAKI 20 Sep 2016 H MAKI ...
Страница 74: ...INDEX IN 2 Z Zoom display 4 8 ...