6. MAINTENANCE, TROUBLESHOOTING
6-4
6.4
Transducer Maintenance
When the ship is dry-docked, remove marine growth from the transducer with fine
sandpaper or a piece of wood.
6.5
How to Replace the Fuses
The fuse in the hull and transceiver units protect them from overvoltage, equipment
fault and reverse polarity of the ship’s mains. If the power cannot be applied first check
that the power cable between the transceiver unit and the display unit is firmly con-
nected. If the power still cannot be applied, the fuse in the transceiver unit may have
blown.
Have a qualified technician check and change the fuse.
Unit
Fuse type
Code No.
Transceiver Unit
FGMB 125V 8A
000-191-004-10
Hull Unit
0287010.U
000-193-054-10
FGMB 125V 6A
000-157-492-10
NOTICE
Do not paint the transducer face with
sunbstances other than anti-foulant.
Loss of sensitivity will result.
Do not use plastic solvents to clean the
transducer.
They can damage the transducer.
Use of the wrong fuse can cause
fire or damage the equipment.
Use the proper fuse.
WARNING