background image

EQUIPMENT LISTS

xx

Console type (RCN-319/323/327/305/306)

Optional supply

Name

Type

Code No.

Qty.

Remarks

Standard 
Console

RCN-319

-

1

For 19-inch monitor

RCN-323

-

For 23.1-inch monitor

RCN-327

-

For 27-inch monitor

Spare Parts

SP03-19200

000-034-305

1

For X-band radar, S-band 
(24rpm) radar, without HUBs.

SP03-19210

000-034-306

For S-band (42rpm) radar, 
without HUBs.

SP03-19220

000-034-307

For X-band radar, S-band 
(24rpm) radar, w/ HUB-100.

SP03-19230

000-034-308

For S-band (42rpm) radar, w/
HUB-100.

SP03-19240

000-034-309

For X-band radar, S-band 
(24rpm) radar, w/ HUB-3000.

SP03-19250

000-034-310

For S-band (42rpm) radar, w/ 
HUB-3000.

SP03-19260

000-034-311

For X-band radar, S-band 
(24rpm) radar, w/ HUB-100 
and HUB-3000.

SP03-19270

000-034-312

For S-band (42rpm) radar, w/ 
HUB-100 and HUB-3000.

Installation 
Materials

CP03-38000

000-034-321

1

Accessories

FP03-12700

000-034-322

1

For RCN-319/323/327

FP03-12800

000-036-847

1

For RCN-305/306

Name

Type

Code No.

Remarks

Control Unit

RCU-014

-

Standard type

RCU-015

-

Trackball type

RCU-016

-

Trackball type

RCU-031

-

Compact type

Junction Box

RJB-001

000-083-355

AD Converter

AD-100-E

-

Signal Cable Assy.

S03-9-5 (8-8P)

008-206-640

For sub monitor of ECDIS, 5 m, 
RW-4864 w/VH8 connector 

S03-9-10 (8-8P)

008-206-650

For sub monitor of ECDIS, 10 m, 
RW-4864 w/VH8 connector 

S03-9-15 (8-8P)

008-209-160

For sub monitor of ECDIS, 15 m, 
RW-4864 w/VH8 connector 

Switching HUB

HUB-100

-

Intelligent HUB

HUB-3000

-

Deicer Kit

OP03-226

001-254-320

For X-band, TR-UP radar

OP03-227

001-254-330

For S-band, TR-UP radar

OP03-231

001-305-060

For X-band, TR-DOWN radar

OP03-232

001-305-070

For S-band, TR-DOWN radar

Installation
Materials

CP03-28900(10M)

000-082-658

LAN cable for sensor network

CP03-28910(20M)

000-082-659

CP03-28920(30M)

000-082-660

Содержание 2258

Страница 1: ...NG 2 1 2 1 Overview 2 1 2 2 Antenna Unit for X band TR UP Radar 2 6 2 3 Antenna Unit for X band TR DOWN Radar 2 19 2 4 Antenna Unit for S band TR UP Radar 2 25 2 5 Antenna Unit for S band TR DOWN Radar 2 37 2 6 Power Supply Unit 2 43 2 7 Transceiver Unit 2 50 2 8 Processor Unit 2 56 2 9 Monitor Unit 2 63 2 10 LAN Signal Converter 2 64 2 11 Junction Box option 2 68 2 12 Intelligent HUB option 2 69 ...

Страница 2: ... elemental chlorine free FURUNO Authorized Distributor Dealer 9 52 Ashihara cho Nishinomiya 662 8580 JAPAN Printed in Japan All rights reserved A NOV 2017 N21 MAR 25 2021 Pub No IME 36520 N21 AKMU FAR 2xx8 series 0 0 0 1 9 8 1 0 4 1 2 ...

Страница 3: ... not open the equipment This equipment uses high voltage electricity which can shock burn or cause serious injury Only qualified personnel can work inside the equipment WARNING Turn off the power at the mains switchboard before beginning the installation Fire electrical shock or serious injury can result if the power is left on or is applied while the equipment is being installed Be sure that the ...

Страница 4: ...ectors XN12CF XN20CF XN24CF 0 6 m 0 4 m 0 3 m 1 3 m 1 0 m 0 7 m 1 4 m 0 9 m 0 6 m 2 7 m 1 7 m 1 3 m 4 4 m 3 0 m 2 5 m 9 5 m 6 8 m 5 5 m FAR 2328W FAR 2238S BB FAR 2338S NXT FAR 2238S NXT BB FAR 2338SW XN20CF XN24CF SN24CF SN30CF SN36CF SN30AF SN36AF SN30DF SN24CF SN30CF SN36CF SN36CF 0 5 m 0 3 m N A 0 26 m 2 3 m 1 2 m 0 9 m 5 5 m 4 0 m WARNING Model Transceiver Magnetron FNE1201 MG5436 MG5223F MG5...

Страница 5: ...S band TR UP solid state radar Antenna Unit S band TR UP magnetron radar Antenna Unit X band TR UP solid state radar 1 90 m 1 20 m Antenna Unit X band TR DOWN 1 55 m 0 95 m Antenna Unit S band TR DOWN 0 85 m 0 55 m 0 90 m 0 55 m 0 50 m 0 30 m 0 95 m 0 60 m 0 95 m 0 60 m 2 85 m 1 80 m 1 65 m 1 05 m Unit Control Unit RCU 014 Control Unit RCU 015 Control Unit RCU 016 Control Unit RCU 031 Processor Un...

Страница 6: ...RCU 014 or RCU 015 or RCU 031 11 Intelligent Hub HUB 3000 5 Gyrocompass 1 AD 10 format Gyrocompass 1 IEC61162 format AIS Transponder EPFS 2 GPS SDME Speed log AMS IEC61162 format Sub monitor 1 of ECDIS 8 Sub monitor 2 of ECDIS 8 AMS Contact 4 Sub monitor Antenna Cable 10 100 115 220 230 VAC 1ø 50 60 Hz for de icer Processor Unit RPU 025 100 230 VAC 100 230 VAC Intelligent Hub HUB 3000 6 100 230 VA...

Страница 7: ...Hz External radar Sub monitor 2 Power Supply Unit PSU 019 Sensors IEC61162 450 format Antenna Cable Sub monitor 3 Sub monitor 1 100 230 VAC 1ø 50 60 Hz VDR IEC61162 450 format Monitor Unit 3 MU 190 or MU 231 or MU 270W Control Unit RCU 014 RCU 015 RCU 031 11 Intelligent Hub HUB 3000 5 Switching Hub HUB 100 6 Control Unit RCU 014 RCU 015 RCU 031 11 Control Unit RCU 016 Processor Unit RPU 025 Intell...

Страница 8: ...Antenna Unit for FAR 2238S NXT BB 2338S NXT 250 W w Performance Monitor PM 52B 7 SN24CF RSB133 111 11 SN30CF RSB133 111 11 SN36CF RSB133 111 Sub monitor 1 of ECDIS 8 Sub monitor 2 of ECDIS 8 Control Unit RCU 014 or RCU 015 or RCU 031 11 Control Unit RCU 016 Standard supply Optional or local supply USB Device 9 USB Mouse 100 230 VAC 1ø 50 60 Hz Transformer 440 VAC 1ø 50 60 Hz Switching Hub HUB 100 ...

Страница 9: ...or 2 Power Supply Unit PSU 019 Sensors IEC61162 450 format Antenna Cable Sub monitor 3 Sub monitor 1 100 230 VAC 1ø 50 60 Hz VDR IEC61162 450 format Control Unit RCU 014 RCU 015 RCU 031 11 Intelligent Hub HUB 3000 5 Switching Hub HUB 100 6 Control Unit RCU 014 RCU 015 RCU 031 11 Control Unit RCU 016 Processor Unit RPU 025 Intelligent Hub HUB 3000 OR Gyrocompass 1 AD 10 format Gyrocompass 1 IEC6116...

Страница 10: ...rformance Monitor PM 32A XN20CF RSB130 XN24CF RSB130 Wave guide Signal cable Sub monitor 1 of ECDIS 8 Sub monitor 2 of ECDIS 8 Control Unit RCU 016 Standard supply Optional or local supply USB Device 9 USB Mouse 100 230 VAC 1ø 50 60 Hz Transformer 440 VAC 1ø 50 60 Hz Switching Hub HUB 100 Monitor Unit 3 MU 190 or MU 231 or MU 270W Intelligent Hub HUB 3000 5 100 230 VAC 100 230 VAC Intelligent Hub ...

Страница 11: ...PM 52A SN36CF RSB131 Coaxial cable Signal cable Processor Unit RPU 025 Sub monitor 1 of ECDIS 8 Sub monitor 2 of ECDIS 8 Control Unit RCU 014 or RCU 015 Control Unit RCU 016 Standard supply Optional or local supply USB Device 9 USB Mouse 100 230 VAC 1ø 50 60 Hz Transformer 440 VAC 1ø 50 60 Hz Switching Hub HUB 100 Monitor Unit 3 MU 190 or MU 231 or MU 270W Intelligent Hub HUB 3000 5 100 230 VAC 10...

Страница 12: ...For BB type a monitor unit is prepared by user 4 Characteristics of contact output for Alarm Load current 250 mA Polarity Normally Open 2 ports Normally Close 2 ports Serial I O for alarm is also possible which complies with IEC 61162 1 5 For configurations with 3 or more radars ECDIS FMD 3100 FMD 3200 FMD 3300 connect ed connect via the HUB 3000 For 2 radars HUB 100 can be used Connection to a FM...

Страница 13: ...CEIVER UNIT LAN LAN1 100 115 220 230 VAC for de icer Sub Monitor Gateway network equipment Radar ECDIS etc Serial LAN2 LAN2 Digital Out 6 Power fail system fail NO 2 NC 2 Digital in ACK in HDG AIS IEC 61162 2 GPS LOG AMS ECDIS IEC 61162 1 Digital Out 6 Power fail system fail NO 2 NC 2 Digital in ACK in Monitor Unit MU 190 MU 231 MU 270W MU 190HD or equivalent for BB model Monitor Unit MU 190 MU 23...

Страница 14: ...ry in advance Note 3 If the software with version 01 is changed to the software with version 50 the RP board in the processor unit is required and the software update of the RP board required as well Band TR UP DN RADAR MODEL TRANSCEIVER UNIT ANTENNA UNIT Remarks X TR UP FAR 2218 BB FAR 2318 RTR 105 XN12CF RSB128 XN20CF RSB128 XN24CF RSB128 FAR 2228 BB FAR 2328 RTR 106 FAR 2228 NXT BB FAR 2328 NXT...

Страница 15: ...r Plotter functionality Function Menu items Type Remarks for software ver IMO A B C R W SCANNER DUAL RADAR SETTINGS For 01 xx ver INSTALLA TION RANGE UNIT ICE MODE SETTINGS For 01 xx ver TT PRESET TT NO For 50 xx ver ALERT I F SETTINGS ALERT OUT 1 2 3 4 DESTINATION LEAVE INTRUSION BAN WATER TEMP ALERT CURRENT RIP DEPTH ALERT TARGET ALARM For 50 xx ver AIS CAPACITY FULL A For 01 xx ver AIS CAPACITY...

Страница 16: ...tandard type RCU 015 Trackball type RCU 031 For BB type of C type radars Installation Materials CP03 35201 001 249 860 1 For radiator CP03 35401 001 254 980 1 For RSB no de icer CP03 35403 001 270 070 For RSB w de icer CP03 35500 15M 000 024 096 1 For Antenna Unit 15 m CP03 35510 30M 000 024 097 For Antenna Unit 30 m CP03 35520 40M 000 024 098 For Antenna Unit 40 m CP03 35530 50M 000 024 099 For A...

Страница 17: ...30M 000 017 043 For Antenna Unit 30 m CP03 33340 50M 000 036 639 For Antenna Unit 50 m CP03 33350 70M 000 036 640 For Antenna Unit 70 m CP03 38900 5M 000 036 633 1 Cable for RPU 025 5 m CP03 38910 10M 000 036 634 Cable for RPU 025 10 m CP03 38920 15M 000 036 635 Cable for RPU 025 15 m CP03 38930 30M 000 036 636 Cable for RPU 025 30 m CP03 38940 40M 000 036 637 Cable for RPU 025 40 m CP03 38950 50M...

Страница 18: ...trol Unit RCU 014 1 Standard type RCU 015 Trackball type RCU 031 For BB type of C type radars Installation Materials CP03 35202 001 249 880 1 For radiator CP03 35402 001 255 430 1 For RSB no de icer CP03 35404 001 270 080 1 For RSB w de icer CP03 35500 15M 000 024 096 1 For Antenna Unit 15 m CP03 35510 30M 000 024 097 For Antenna Unit 30 m CP03 35520 40M 000 024 098 For Antenna Unit 40 m CP03 3553...

Страница 19: ...036 640 For Antenna Unit 70 m CP03 38900 5M 000 036 633 1 Cable for RPU 025 5 m CP03 38910 10M 000 036 634 Cable for RPU 025 10 m CP03 38920 15M 000 036 635 Cable for RPU 025 15 m CP03 38930 30M 000 036 636 Cable for RPU 025 30 m CP03 38940 40M 000 036 637 Cable for RPU 025 40 m CP03 38950 50M 000 036 638 Cable for RPU 025 50 m CP03 38960 1 5M 000 036 786 Cable for RPU 025 1 5 m CP03 37801 001 489...

Страница 20: ...M 000 024 096 1 For Antenna Unit 15 m CP03 35510 30M 000 024 097 For Antenna Unit 30 m CP03 35520 40M 000 024 098 For Antenna Unit 40 m CP03 35530 50M 000 024 099 For Antenna Unit 50 m CP03 37801 001 489 150 1 For RPU 025 CP03 25604 001 418 420 1 For RCU 014 015 CP03 16400 000 086 743 1 w CP03 16401 CP03 16410 000 086 744 Flexible waveguide 20 m w CP03 16411 CP03 16420 000 086 745 Flexible wavegui...

Страница 21: ... Antenna Unit 15 m CP03 35510 30M 000 024 097 For Antenna Unit 30 m CP03 35520 40M 000 024 098 For Antenna Unit 40 m CP03 35530 50M 000 024 099 For Antenna Unit 50 m CP03 37801 001 489 150 1 For RPU 025 CP03 25604 001 418 420 1 For RCU 014 015 CP03 36300 000 025 573 1 Coax cable 20 m CP03 36310 000 025 574 Coax cable 30 m Accessories FP03 09880 001 574 480 1 For RCU 014 FP03 09860 001 419 140 1 Fo...

Страница 22: ... Installation Materials CP03 38000 000 034 321 1 Accessories FP03 12700 000 034 322 1 For RCN 319 323 327 FP03 12800 000 036 847 1 For RCN 305 306 Name Type Code No Remarks Control Unit RCU 014 Standard type RCU 015 Trackball type RCU 016 Trackball type RCU 031 Compact type Junction Box RJB 001 000 083 355 AD Converter AD 100 E Signal Cable Assy S03 9 5 8 8P 008 206 640 For sub monitor of ECDIS 5 ...

Страница 23: ...onnector S03 92 40 8P 001 259 910 For sub monitor 40 m RW 00136 w VH8 connector S03 92 50 8P 001 259 920 For sub monitor 50 m RW 00136 w VH8 connector S03 92 70 8P 001 559 440 For sub monitor 70 m RW 00136 w VH8 connector Bracket Assembly OP26 21 001 139 310 For MU 190 connection Connection stand 19 OP26 20 001 139 300 For MU 190 connection Clamp Assembly OP03 182 008 535 620 For RCU 014 Cable Ass...

Страница 24: ...1 490 580 For RCN 319 Back Cover 23 OP24 54 001 490 590 For RCN 323 Back Cover 27 OP24 55 001 490 600 For RCN 327 Console Kit RCN319N RCN323 327N Bracket Assembly OP26 5 000 016 270 For MU 190 190HD OP26 15 001 116 730 For MU 231 OP26 30 001 439 060 For MU 270W LAN Signal Converter OP03 247 1 001 496 560 For RSB 133 OP03 247 2 001 496 570 For RSB 129 OP03 247 3 001 496 580 For RSB 128 magnetron ra...

Страница 25: ...36520 000 193 878 English OMJ 36520 000 193 877 Japanese Waveguide Tool BSH 15279 001 461 510 For S band TR DOWN radar Waveguide Twisted RWA 1050 C 109 001 304 660 For X band TR DOWN radar Waveguide H Bend RWA 1040 B 108 001 304 650 Waveguide E Bend RWA 1030 B 107 001 304 640 Bracket For Rectguide OP03 148 008 477 540 FR 9 Less Flex Wave Guide FR 9 00 001 102 740 Drain Waveguide 03 009 0360 001 35...

Отзывы: