Splice-On-Connector Quick Reference Guide - 250 & 900
µ
m
1
2
3
4
5
6
7
8
9
Remove ferrule from
packaging using ferrule
transportation tool.
Place ferrule in ferrule
holder using ferrule
transportation tool.
Place ferrule holder
directly into fusion splicer
Slide field fiber through
main body connector parts
inside packaging. Then
remove.
Slide included 20mm
protection sleeve onto field
fiber.
Load fiber into fiber holder
leaving approximately 1.25
inches protruding from holder.
Prepare field fiber for
fusion splicing using
standard procedure.
Slide splice sleeve over
spliced fiber
Protect splice with heat
shrink oven
Remove Transportation Tool
Slide outer housing over
inner housing. Inner housing
is keyed to outer housing.
COMPLETE!
10
11
12
14
15
Slide up main body and spring.
Place inner housing over main
body and ferrule (for APC align
dot with round side of inner
housing). Main body is keyed to
inner housing.
Use Connector Assem-
bling Tool to snap on
inner housing to main
body.
13