FCO770 Users Guide Issue 1
Page 41
PRODUCT DATA MENU
Identify the product to test and define the test steps to perform. When you select the menu
you must select the product to view/edit from a list.
PRODUCT SELECTED
•
Select the product number from the list of products displayed. All the products
parameters will then be available to alter.
BARCODE I/D
•
When a barcode reader is used for product selection you may enter up to 16 characters
that the barcode must successfully match for the product to be selected. The ‘wild
card’ characters shown below may be used to match variable numeric or alphabetic
characters. Any other characters must match exactly.
•
The ‘wild card’ characters are:
o
#
0 to 9 or # required
o
&
A-Z or & required (upper or lower case is accepted)
o
?
A character is required but the actual character is not checked.
o
Space
Character position is not checked
NUMBER OF STEPS
•
Set the number of steps required to test the product.
•
A product may have up to sixteen different tests applied.
DELAY BETWEEN STEPS
•
This is a time delay between steps to allow for jigging changes etc. The delay time is
common to all steps.
•
The delay may be set from 0.00 to 99.99 seconds.
STEP 1
→
16
•
Select the test to be used for each of the number of steps set above.
CONTINUE ON
•
When there is more than one step, define the conditions required to continue to the
next step. If the condition is not met the instrument will fail the product and terminate
the test.
•
Options: RESULT, PASS, FAIL 1, PASS/FAIL1, FAIL, START