Frame Relay
bintec User’s Guide
25
Multiprotocol over Frame Relay Submenu
4
Destination IP Address
Only for
R
OUTE
T
YPE
=
Host route
or
Network
route
.
IP address of the destination host or LAN.
Netmask
Only for
R
OUTE
T
YPE
=
Network route
.
Netmask for
D
ESTINATION
IP-A
DDRESS
.
Partner / Interface
Only for
N
ETWORK
=
WAN without transit
network
.
Displays the connection partner. Field cannot
be modified.
Mode
Only for
N
ETWORK
=
WAN without transit
network
.
Defines when the connection partner is to be
used. Possible values see
selection options,” on page 26.
Metric
The lower the value, the higher the priority of
the route (possible values
0
...
15
).
Default value is
1
.
Source Interface
Interface over which the data packets reach the
gateway.
Default value is
don’t verify
.
Source IP-Address
IP address of the source host or LAN.
Source Mask
Netmask for
S
OURCE
IP-A
DDRESS
.
Type of Service (TOS)
Possible values:
0
..
255
as bit string.
TOS Mask
Bit mask for
T
YPE
OF
S
ERVICE
.
Protocol
Defines a protocol. Possible values:
don’t verify, icmp, ggp, tcp, egp, pup, udp,
hmp, xns, rdp, rsvp, gre, esp, ah, igrp, ospf,
l2tp.
Default value is
don’t verify
.
Field