Field
Description
Possible values are
1
to
99
.
The default value is
5
.
Fields in the OAM Control CC Activation
Field
Description
Continuity Check (CC)
End-to-End
Select whether you activate the OAM-CC test for the connection
between the endpoints of the VCC or VPC.
Possible values:
•
Passive
(default value) OAM CC requests are responded to
after CC negotiation (CC activation negotiation).
•
Active
: OAM CC requests are sent after CC negotiation (CC
activation negotiation).
•
Both
: OAM CC requests are sent and answered after CC ne-
gotiation (CC activation negotiation).
•
No Negotiation
: Depending on the setting in the Direc-
tion field, OAM CC requests are either sent and/or responded
to. There is no CC negotiation.
•
None
: The function is disabled.
Also select whether the test cells of the OAM CC are to be sent
or received.
Possible values:
•
Both
(default value): CC data is both received and generated.
•
Sink
: CC data is received.
•
Source
: CC data is generated.
•
None
: The function is disabled.
Continuity Check (CC)
Segment
Select whether you want to activate the OAM-CC test for the
segment connection (segment = connection of the local end-
point to the next connection point) of the VCC or VPC.
Possible values:
•
Passive
(default value) OAM CC requests are responded to
after CC negotiation (CC activation negotiation).
•
Active
: OAM CC requests are sent after CC negotiation (CC
10 WAN
Funkwerk Enterprise Communications GmbH
300
bintec R1xxx/R3xxx/R4xxx