 8.General Safety Instructions

 8. General Safety Instructions

Please read the manual carefully before installation and setup of your device.
The relevant regulations must be complied to when working with 230V line voltage, two-wire-

lines, four-wire-lines and ISDN-lines. It is also very important to comply to the regulations and
safety instructions of working with radio installations.

Please comply to the following safety rules:

All components may only be mounted and maintained when power is off.

The modules may only be activated if they are built in a housing and are scoop-proof.

Devices which are operated with external voltage – especially mains voltage – may only be

opened when they have been disconnected from the voltage source or mains.

All connection cables of the electronic devices must be checked for damage regularly and must

be exchanged if damaged.

Absolutely comply to the regular inspections required by law according to VDE 0701 und 0702

for line-operated devices.

Tools must not be used near or directly at concealed or visible power lines and conductor paths

and also not at and in devices using external voltage – especially mains voltage – as long as the
power   supply   voltage   has   not   been   turned   off   and   all   capacitors   have   been   discharged.

Electrolytic capacitors can be still charged for a long time after turning off.

When using components, modules, devices or circuits and equipment the threshold values of

voltage, current and power consumption specified in the technical data must absolutely be
complied to. Exceeding these threshold values (even if only briefly) can lead to significant

damage.

The devices, components or circuits described in this manual are only adapted for the specified

usage.  If  you  are  not  sure  about  the  purpose  of  the  product,  please  ask your  specialized
distributor.

The installation and setup have to be carried out by professional personnel.

 9. Returning of Old Equipment

According to German law concerning electronic devices, old devices cannot be disposed off as regular
waste. Our devices are classified for commercial use only. According to § 11 of our general terms of

payment and delivery, as of August 2015, the purchasers or users are obliged to return old equipment by us
free   of   cost.   FunkTronic   GmbH   will   dispose   of   this   old   equipment   at   its   own   expense   according   to

regulations.

Please send old equipment for disposal to:

FunkTronic GmbH

Breitwiesenstr. 4
36381 Schlüchtern

GERMANY

>>> Important: 

Freight forward deliveries cannot be accepted by us!

Subject to change, errors excepted!

-12-

MBOS8VD_eng (15.11.17)

Содержание Major BOS 8VD

Страница 1: ...Major BOS 8VD Manual VoIP control panel for up to 8 digital TETRA and or analogous radio terminals...

Страница 2: ...D 4 3 1 Display standard operation 5 3 2 Men steuerung 6 4 Connectivity 7 5 Pin layout 8 6 Configuration via web interface 10 6 1 Restoring the default IP address 10 7 Technical data 11 8 General Safe...

Страница 3: ...devices can also be used with Major BOS 8VD as there are the footswitch headsets magnetic fixation for handset metal holder for sunk in table mounting power over ethernet PoE As with all our VoIP dev...

Страница 4: ...OK 3 Volume buttons VOL Menu 4 Volume display LED band 5 Volume buttons VOL Menu 6 Loudspeaker buttons on off Go back 7 Function F2 programmable 8 Function F1 programmable 9 PTT X Escape 10 Loudspeak...

Страница 5: ...hose informations are displayed if the choice of several radios is possible radio with lowest number is displayed Signal Radio Signal Strength Mode of Operation TMO DMO GW REP Time Current time as rec...

Страница 6: ...ffnen des Hauptmen s f r den jeweiligen Funkkreis muss die entsprechende Men taste Kreistaste 1 Sekunde lang gedr ckt werden Im Hauptmen erfolgt die Anwahl der Optionen mit OK Zum bergeordneten Men b...

Страница 7: ...nection of two MRTs via ethernet For the connection of analogous radios the IP interface FT636B is used 2 radios per interface If desired one of the 8 radio circuits can be used to just communicate be...

Страница 8: ...pin RS232 interface programmable I Os 1 8 1 TXD output 2 RXD input 3 GND 4 I O 0 5 I O 1 6 I O 2 7 I O 3 8 I O 4 Socket PTT Connection of ext PTT e g foot switch or headset adapter not necessary for...

Страница 9: ...e 5 GND AF in mic 6 GND PTT HS1 Socket S E 8 wire socket for connection of analogous device 1 8 1 NF in A 2 NF in B 3 SQL in S E mit Pullup 4 GND 5 BATT out Do not connect to radio 6 PTT S E in out 7...

Страница 10: ...update 9999 TCP protocol Please be aware that all devices that need to be connected have to be in the same subnet 6 1 Restoring the default IP address If the IP address of the Major BOS 8VD is not kn...

Страница 11: ...99 dB bis 26 dB 200 Ohm Input impedance 600 Ohm Output level S E Factory setting 500 mV 3 8 dB 200 Ohm Adjustment range 99 dB bis 26 dB Output impedance ca 200 Ohm Output level for earphone headset RX...

Страница 12: ...the power supply voltage has not been turned off and all capacitors have been discharged Electrolytic capacitors can be still charged for a long time after turning off When using components modules de...

Страница 13: ...Major BOS 8VD 10 Release Notes 10 Release Notes 15 11 17 First version 13 MBOS8VD_eng 15 11 17...

Отзывы: