5-2
LC8.5P(LED)EA
1. Purity Check Mode
This mode cycles through full-screen displays of red,
green, blue, and white to check for non-active pixels.
1. Enter the Service mode.
2. Each time pressing [7] button on the remote
control unit, the display changes as follows.
3. To cancel or to exit from the Purity Check Mode,
press [BACK] button.
2. VCOM Adjustment
1. Operate the unit for more than 20 minutes.
2. Set the color analyzer at the zero point calibration
and bring the optical receptor pointing at the
center of the LCD-Panel at a distance of 3cm away
from the LCD-Panel surface.
Note:
The optical receptor must be set
perpendicularly to the LCD Panel surface.
3. Enter the Service mode.
4. To enter the “VCOM-2 adjustment mode”, press [3]
button on the remote control unit.
To enter the “VCOM-1 adjustment mode”, press [2]
button on the remote control unit.
5. Press [P
/
] buttons on the remote control
unit so that the color analyzer value becomes
minimum.
6. To cancel or to exit from the VCOM Adjustment,
press [BACK] button.
[7] button
Note:
When entering this mode, the default setting is White mode.
Purity Check Mode
[7] button
Red mode
Green mode
Blue mode
Black mode
[7] button
White mode
[7] button
[7] button
White 20% mode
[7] button
Test Point
Adj. Point
Screen
[P
/
]
buttons
M. EQ.
Spec.
Color analyzer
See below
Figure
Color Analyzer
To avoid interference from ambient
light, this adjustment should be
performed in a dark room.
L = 3 cm
Perpendicularity
Содержание LED19-H800M
Страница 13: ...4 2 A0CN6_N7DC 2 Rear Cabinet 1 Stand Assembly S 1 S 2 S 2 S 2 S 3 S 2 S 2 S 2 S 4 L 1 L 1 L 1 Fig D1 ...
Страница 35: ...10 3 A0CN6SCP1 Power Supply 1 Schematic Diagram ...
Страница 37: ...10 5 Jack 1 Schematic Diagram A0CN6SCJ1 ...
Страница 39: ...10 7 IR Sensor Schematic Diagram Function Schematic Diagram A0CN6SCF A0CN6SCIR ...
Страница 71: ...LED19 T800M LED19 H800M A0CN6EP A0CN7EP 2011 01 14 Ver 1 ...