REMOTE USER INTERFACE FOR
MICROSOL II PLUS
W
ALLLINK01-01T
-1
1868
5. FUNCTION MENU
The function menu allows configuring Microsol II plus controller functions remotely. To access the
function menu press
and
keys simultaneously for two seconds until the functions are shown
in the display. To access any function and confirm the value press
; to go back to the previous
menu or to leave any function without confirming press
. The following options are available in the
function menu:
1. DESCRIPTION
2. APPLICATION
3. TECHNICAL SPECIFICATIONS
4. MAIN SCREEN
Wall-Link
Wall-Link
is an interface intended to be used together with Microsol II plus from version 2 and
above.
It enables easy and quick remote access to all Microsol II plus information and setup.
Solar heating controlling.
- Power supply: 90 - 264 Vac (50/60 Hz)
- Size: 90 x 131 x 28 mm (W x H x D)
- Operating temperature: 0 to 50°C
- Operating humidity: 10 to 90% RH (no condensation)
- Data communication: by wire - maximum distance of 1000 meters
The figure below shows the main screen of
with the system in operation.
01-Access Code
02-Functions
03-Schedule Mode
04-Schedule Evt
05-Clock
Preferential indication
description
Preferential indication
value
Swimming pool
26.9$C
5.1 Access code
5.2 Functions
5.3 Event scheduling mode
5.4 Event scheduling
5.5 Clock adjustment
6. QUICK ACCESS MENU
The access code 123 must be entered in this screen to enable changing functions of Microsol II plus
controller. To enter the code press
on the message and adjust the value that will be blinking on the
display. Press
again to confirm; to cancel and go back press
.
In this screen all functions of Microsol II plus can be adjusted. To make changes press
on the
desired function and enter the value that will be blinking on the display. Press
again to confirm the
new value; to cancel and go back press
.
The operating mode of Microsol II plus event scheduling can be programmed from this screen.
The schedule of the remote instrument can be viewed and changed by accessing this function with the
key
. To inform or change the configuration press
on the option corresponding to the event
and day of the week. Adjust the time of beginning and end of the event using the
and
keys,
press
to confirm the new value; to cancel and go back press
.
To go back or to leave the options press
at any time.
To adjust the internal clock of Microsol II plus select this function by pressing
. Then adjust the
values using the
and
and press
to confirm or
to cancel.
To go back or to leave the options press
at any time.
The quick access menu allows configuring the setpoints of supports 1 and 2, as well as the manual
operating modes and the overheating temperature for sensor 1. To access this menu, press
shortly
while
main screen is displayed. To access any function and confirm the value press
; to
Wall-Link
Function
description
Function code
Function value
On Dif Temp
dOn@ 10.0 #
Function unit
Monday
E02@ 09:40/18:50
Day of week
Day event
Start time
Finish time
back to the previous menu or to leave any function without confirming press
.
The following options are available in the function menu:
This function allows adjusting the control temperature for auxiliary output 1.
This function allows adjusting the control temperature for auxiliary output 2.
This function allows adjusting the overheating temperature for sensor 2. When applied to swimming
pools this is the limit temperature of the water (comfort temperature)
This function allows adjusting the manual operating mode of the water pump.
The operating mode of the auxiliary 1 output can be toggled between manual and automatic by
pressing
on this function.
The operating mode of the auxiliary 2 output can be toggled between manual and automatic by
pressing
on this function. Note: This option will be only available when the Microsol II plus is
version 03.
Upon accessing the quick access menu while
is not connected to Microsol II plus, the user
will have two functions available for adjusting the address of Microsol II plus:
The address of Microsol II plus controller can be manually adjusted by entering this function. The value
of this function must be the same value configured in Microsol II plus.
6.1 Auxiliary 1 setpoint
6.2 Auxiliary 2 setpoint
6.3 Sensor 2 overheating temperature
6.4 Water pump operating mode
6.5 Auxiliary 1 manual mode enable
6.6 Auxiliary 2 manual mode enable
7. ACCESS MENU FOR ADJUSTING THE CONNECTION
7.1 Microsol II plus address
Wall-Link
03-S2 Hi Temp
05-A1 Man Mode
04-Pmp Activat
01-McSol 485 Add
02-Search McSol
06-A2 Man Mode
Only with Microsol II plus from version 03
01-Setpoint A1
02-Setpoint A2
7.2 Search Microsol II plus
8. SETUP MENU
8.1 McSol2 485 Add
8.2 Interface
Pressing
on this function makes
start searching for Microsol II plus address
automatically. Enter the quick access menu again to stop the automatic search.
The operating characteristics of
can be adjusted through the setup menu. To access the
function menu press
and
keys simultaneously for eight seconds until the functions are shown
in the display. The following options are available in the setup menu:
This function allows to manually adjusting the address of the Microsol II plus controller.
The value set for this function should be the same value set on the Microsol II plus.
Allows adjusting the user interface characteristics:
Wall-Link
Wall-Link
01-McSol 485 Add
04-Timeouts
02-Interface
03-Descriptions
05-Statistics
Descrição
Mín.
Máx.
Unid
Fun
Padrão
S1
-
1
0
Off
All
-
10
999
On
-
-
-
min.
-
Indication
Language
Display contrast
Display timeout
Sound signaling
S2
Port
5
0
Off
I01
I02
I03
I04
I05