DIFFERENTIAL THERMOSTAT FOR SOLAR
HEATING OR DIGITAL THERMOSTAT
Anasol
is a differential thermostat for solar heating with two sensors and one output for controlling a
water circulation pump. The controller also has protection functions that prevent water from overheating
or freezing in the solar collector. It can also be configured as a digital thermostat with control logic for
heating or cooling. The interface used allows the simple display of SAS information, such as: output
status (differential or thermostat), operation mode (automatic, manual or off), and sensor temperature.
- Solar heating for swimming pool or thermal reservoir;
- Water heaters
- Air-conditioning;
Set the comfort temperature (SP) of the pool or thermal reservoir (T2). The water pump will
switch off when this temperature is reached, avoiding thermal discomfort. In the thermostat
mode, it sets the operating temperature of the thermostat (T1).
To set this parameter, press the
key. Use the
or
keys to set the value. To confirm, press
SET
UpP
DOWN
shortly the
key and the value will be saved in the controller memory. This parameter can be
SET
adjusted between the values defined in the advanced configuration
[F09]
- minimum value and
[F10]
- maximum value
Using the
it is possible to change the operating mode of the water pump. The water circulation
MMMM
pump between the solar collector and the thermal reservoir can operate on three different modes.
Note¹: When the MAN (MANUAL) mode is selected, the pump will operate in this state for the length of
time set by the
[F08]
function - The maximum length of time the output will remain on in manual mode.
After this, the controller switches to the AUT (AUTOMATIC) mode.
The controller has easy access to features relevant to the user. The controller’s operating mode is
defined by parameter
[F06]
- Operating Mode. See a table and description below.
4.3.1 DIFFERENTIAL MODE (SOLAR HEATING):
4.3.2 THERMOSTAT MODE:
- Short press: changes the pump mode (AUT - MAN - OFF).
- Short press: changes the output mode (MAN - OFF)
- Long press (4 seconds): changes the output mode (AUT - OFF)
Note: In the automatic mode: short pressing
activates the output considering the configured
DDDD
parameters
- Short press: set the pool / reservoir heating temperature.
- Long press (4 seconds): access advanced settings.
- Short press: set the thermostat temperature.
- Long press (4 seconds): access advanced settings.
- Short press: briefly displays the remaining time (in minutes) of the manual mode timer.
- Short press: briefly displays the remaining time (in minutes) of the manual mode timer.
- Short press: changes the temperature display (T1-T2-DIF). After 10 minutes, the preferred
indication returns.
4. INDICATION AND SCREEN
4.2 INDICATIONS
4.1 PRESENTATION
4.3 KEY MAP
5. USER OPERATIONS
3. TECHNICAL SPECIFICATIONS
2. APPLICATIONS
1. DESCRIPTION
Operating temperature
Control Temperature
0 to 50°C
Sensor T1
: -20 to 200°C
Sensor T2
: -20 to 105°C
Operating humidity
Resolution
Product size
Control output
10 a 90% UR (without condensation)
0,1°C between -10 and 100°C and 1°C outside
that range
77 x 39 x 97mm
Down Key
Set Key
Indicates thermostat
control mode
Indicates differential
control mode
Manual pump
operating mode
- Modo de operação da bomba automático.
- Manual pump operation mode.
Note: Both off - OFF: Pump operating mode off.
- Output on - Differential control mode.
- Output on - Thermostat control mode (heating or cooling).
Automatic pump
operation mode
Display
digits
Up Key
Pump Mode Key
Sensors
Sensor T1
: Solar Collector -
SB 59 Sensor, white cable, 1m
Sensor T2
: Thermal Reservoir -
SB19 Sensor, black cable, 2m
Power supply
Anasol 115Vac
: 115Vac ±10% (50/60Hz)
Anasol 230Vac
: 230Vac ±10% (50/60Hz)
5.1 POOL / RESERVOIR HEATING TEMPERATURE (SENSOR T2)
OR THERMOSTAT (SENSOR T1)
5.2 WATER PUMP OPERATING MODE
Short Press
AUT = Circulation pump in automatic mode,
operating in accordance with the set
parameters.
OFF = Pump always off
MAN = Circulation pump turned on
Warning:
In this mode the pump is kept on, by
passing the protection functions (except the
protection: against thermal shock).
Relay output, max. 1HP at 220Vca
(½HP at 127Vca)
or 16A, resistance at 3500W at 220Vca
(1750W at 127Vca)
Note²: This operating mode is available when compatible
[F06]
= diF (Differential Solar Heating
Mode).