Instruction Manual 

HBX-800 BISx I/F UNIT 

(Bispectral Index, BISx Module Interface

 

 

3-39-4 Hongo, Bunkyo-ku, Tokyo, Japan 

Phone:+81-3-5684-1455  Fax:+81-3-3814-1222 

 

Printed in Japan   4L0110810  201401 

Copyright © 2014 by Fukuda Denshi Co., Ltd. 
No part of this document may be copied or transmitted in any form without the prior written permission of 
Fukuda Denshi Co., Ltd. 

z

 Thank you for purchasing this product. 

z

 Before using this product, read through this manual and also refer to the DS-8500 System operation manual. 

z

 After reading, keep this manual near the unit for future reference. 

 

This device bears the CE label in accordance with the provisions of Medical Device Directive 93/42/EEC. 
This device bears the CE label in accordance with the provisions of RoHS Directive 2011/65/EU. 

 

Fukuda Denshi UK 
Unit 7, Genesis Business Park, Albert Drive, Woking, Surrey GU21 5RW, United Kingdom 

 
For details on how to set the monitoring condition, refer to the operation manual of the DS-8500 System or other equipment which the HBX-800 is 
connected to.   
 
 

 

- 1 - 

Safety Precautions

 

HS-8312N/HS-8312M and HBX-800

 

 

Make sure to follow the precautions indicated below, as these are 
important messages related to safety. The followings are descriptions 
and graphic symbols of the safety and precaution messages used in this 
manual. 
 

WARNING

 

Failure to follow this message may result in death 
or serious injury. 

CAUTION

 

Failure to follow this message may cause injury or 
failure to the equipment. 

NOTE

 

A note is not related to product safety, but provides 
information about the correct use and operating 
procedures to prevent incorrect operation and 
malfunction of the equipment. 

 
 

Graphic Symbols 

 

Name of Parts and Their Functions

 

The following are the symbols and their meaning indicated on the 
equipment. 

 

 

 

Symbol Description 

 

Follow operating instructions (Information). 

 

Type BF Applied Part with Defibrillation-Proof 

Indicates the degree of protection against electric 

shock which is Type BF eApplied Part with 
defibrillation-proof.  

 

Electrostatic Sensitive Part 

Directly touching this connector part with hands 

should be avoided. 

 

Signal Input/Output 

 

Year of Manufacture 
Indicates the manufactured year. 

 

WEEE (Waste Electrical and Electronics Equipment)
Indicates a separate collection for electrical and 
electronic equipment. 

 

General Description

 

The HBX-800 is an interface unit between the AUX connector of the 
HS-8312N/HS-8312M (or other equipment which the HBX-800 is 
connected to) and the BISx Module to measure the BIS, SQI, SR and 
EMG. 
 
The HBX-800 is provided with a serial communication connector which 
connects the BISx Module (optional). 

 

Item Function 

1

Power Supply Indicator 

Indicates the power ON/OFF status.
When the power is turned ON and 
BISx Module is not connected, it will 
light in orange. When the BISx 
Module is connected, it will light in 
green. 

2

Serial Communication 
Connector (BISx Input) 

Connects the BISx Module 
(Covidien). 

3

AUX Connection Cable 

Connects to the AUX connector of 
the HS-8312N/HS-8312M. 

 

CAUTION 

If the indicator does not light or lights red when connected to the 
patient monitor, disconnect it and cease using the equipment. 
Contact your nearest service representative. 

2

3

1