Date of installation :

Contact of your heating technician or your after-sales service. 

Su

bj

ec

t t

m

od

ifi

ca

tio

ns

 w

ith

ou

t n

ot

ic

e.

 N

on

 c

on

tra

ct

ua

l d

oc

um

en

t.

This appliance is marked with this symbol. This means that electrical and electronic products shall not be mixed with general household waste. 

European Community countries(*), Norway, Iceland and Liechtenstein should have a dedicated collection system for these products. 

Do not try to dismantle the system yourself as this could have harmful effects on your health and on the environment. 

The dismantling and treatment of refrigerant, oil and other parts must be done by a qualified installer in accordance with relevant local and national regulations. 

This appliance must be treated at a specialized treatment facility for re-use, recycling and other forms of recovery and shall not be disposed of in the municipal 

waste stream. 

Please contact the installer or local authority for more information. 

* subject to the national law of each member state

1 9  Information display

Various  data  can  be  displayed  by  pressing  the  info  

button 

 .

Depending on the type of unit, configuration and operating 

state, some of the info lines listed below may not appear.

 -Error messages : 

The display shows the "Bell" symbol 

.

 

"

Consult your heating technician 

 -Service messages ; Special mode messages : 

The display shows the "Key" symbol 

.

 

"

Consult your heating technician 

Various data (see below).

Designation

Line

Floor drying current setpoint .

-

Current drying day.

-

Terminated drying days.

-

State heat pump.

8006

State supplementary source.

8022

State DHW (domestic hot water).

8003

State heating circuit 1.

8000

State cooling circuit 1.

8004

Outdoor temperature.

8700

Room temperature 1.

8740

Room setpoint 1.
Flow temperature 1.

8743

Flow temperature setpoint1.
DHW (domestic hot water) temperature.

8830

Heat pump return temperature.

8410

Setpoint (return) HP.
Heat pump flow temperature.

8412

Setpoint (flow) HP.

Содержание WATERSTAGE UTW-SCB A Series

Страница 1: ...users To be saved for future consultation UTW SCB A Document n 1408 2 26 07 2010 Fujitsu General Euro GmbH Werftstrasse 20 40549 Düsseldorf Germany Subject to modifications without notice Non contractual document Control Box EN FR NL DE IT ES PT PL LT CZ ...

Страница 2: ...n 4 Quick start up 6 Programming example 7 Structure of the End user control menu 8 Parametering the setting 9 General 9 Setting parameters 9 Information display 11 figure 1 Overall view of the configuration of a complete installation Room control unit Options depending on the system configurations Room thermostat Control options DHW kit Boiler connection kit Heat pump Outdoor sensor or and Contro...

Страница 3: ...diators To ensure the function of the regulation with room influence it s necessary that the room in which the room thermostat is installed has no thermostatic valve or that they must be completely open 1 3 3 Floor heating systems New floor heating systems require to be initially heated slowly to avoid any problems with cracking Check with your installer that this initial heating procedure has ind...

Страница 4: ...n figure 2 User interface of the control box Auto ESC OK RESET 0 4 8 12 16 20 24 1 2 3 4 5 6 7 8 9 figure 3 Room control unit option Auto ESC OK 0 4 8 12 16 20 24 1 2 3 4 5 7 12 8 6 figure 4 Room thermostat option C Auto 5 10 11 12 Operation manual 1408 EN Control Box 4 ...

Страница 5: ... is automatic Constant comfort temperature Constant reduced temperature Stand by mode with anti frost protection Provided that the heat pump s electrical power supply is not interrupted 6 Information display Various data page 12 Reading error codes Information concerning maintenance special mode 7 Confirm OK Input into the selected menu Confirmation of the parameter settings Confirmation of the ad...

Страница 6: ...ace utilisateur Sélectionner le menu Heure et date Appuyer sur OK Heure et date Heures minutes Sélectionner une des lignes Heure minutes ou Jour mois ou Année Appuyer sur OK Effectuer tous les réglages pour valider chaque réglage Appuyer sur OK Revenir à l affichage de base en appuyant sur la touche de régime Heure et date Heures minutes figure 6 Setting the time and the date Press OK Choose menu ...

Страница 7: ...ner le bouton pour régler les minutes Les réglages sont enregistrés Revenir à l affichage de base en appuyant sur la touche de régime Tourner le bouton pour effectuer d autres réglages ou Touches Description Exemple d affichage figure 7 Programming example Keys Display example Description Basic display If the basic display is not shown press ESC to return to it Press OK Room setpoint 1 Time of day...

Страница 8: ...d phase off 3rd phase on 3rd phase off Default values Mon Sun Mon Fri Sat Sun Monday Tuesday Sunday Holidays heating circuit 1 Holidays heating circuit 2 Operation level Period 1 Period 2 Period 8 Heating circuit 1 Heating circuit 2 Comfort setpoint Reduced temp Reduced setpoint Temp frost protect comfort Frost protect setpoint reduced temp Domestic hot water Nominal setpoint Reduced temp Fault Re...

Страница 9: ...f press End user OK OK OK Time of day and date Hours minutes 1 Hour 1 24 h Operator section Day Month 2 Minutes 0 60 min Time prog heating circuit 1 Year 3 Line Function Setting range or display Setting increment Basic setting Date and time 1 Hours Minutes 00 00 23 59 1 2 Day Month 01 01 31 12 1 3 Year 1900 2099 1 Operator section 20 Language English Français Italiano Nederlands English Heating ti...

Страница 10: ...hase On start 00 00 10 min 606 3rd phase Off end 00 00 10 min 616 Default values No Yes No Yes OK The default values memorised in the regulator replace and cancel the customised heating programmes Your customised settings are therefore lost Holidays heating circuit 1 641 Preselection Period 1 to 8 Period 1 642 Start Day Month 01 01 31 12 1 643 End Day Month 01 01 31 12 1 648 Operating level during...

Страница 11: ... uses the boiler connection when a fault occurs error 370 In the On position the energy costs can be onerous if the error is not eliminated Diagnostics heat generation 8410 Return temp HP 0 140 C Setpoint return HP 0 140 C 8412 Flow temp HP 0 140 C Setpoint flow HP 0 140 C 8413 Compressor modulation 0 100 Diagnostics consumers 8700 Outdside temperature 50 50 C 8701 Outside temp min Reset No Yes 50...

Страница 12: ...the municipal waste stream Please contact the installer or local authority for more information subject to the national law of each member state 1 9 Information display Various data can be displayed by pressing the info button Depending on the type of unit configuration and operating state some of the info lines listed below may not appear Error messages The display shows the Bell symbol Consult y...

Отзывы: