Note
-
When
mounting
a
CPU
memory
unit
board,
check
the
connectors
on
both
of
the
CPU
memory
unit
board
and
frame
beforehand
to
confirm
that
no
pin
is
bent
and
all
the
pins
are
neatly
arranged
in
lines.
If
there
is
a
bent
pin
in
a
connector,
mounting
a
CPU
memory
unit
board
may
damage
the
CPU
memory
unit
or
frame.
Also,
carefully
proceed
with
the
work
to
prevent
any
pin
from
being
bent.
Note
-
A
part
of
the
procedure
varies
depending
on
the
CPU
memory
unit
type.
To
determine
the
CPU
memory
unit
type,
check
the
label
in
Note
-
Be
careful
when
removing
the
filler
unit
so
that
it
does
not
catch
on
any
PCIe
cable.
Note
-
Use
PCIe
cables
without
removing
the
packaging
material
covering
the
connector
part
of
the
cable.
Note
-
The
shortest
PCIe
cable
is
no
longer
necessary
during
maintenance.
Connect
it
to
the
removed
CPU
memory
unit,
and
return
them
together.
7.7.1
Installing
the
CPU
memory
unit
upper
Install
the
CPU
memory
unit
upper
on
the
CPU
memory
unit
lower.
When
replacing
the
CPU
memory
unit
lower,
install
the
CPU
memory
unit
upper
on
the
new
CPU
memory
unit
lower.
For
expansion
of
a
CPU
memory
unit
upper,
perform
the
same
procedure.
When
removing
the
CPU
memory
unit
upper,
install
a
filler
unit
in
its
place.
1.
When
installing
a
filler
unit
for
the
CPU
memory
unit
lower
connected
with
PCIe
cables,
move
the
PCIe
cables
(A
and
B
in
the
figure)
further
apart
toward
the
outside
of
the
chassis.
Fujitsu
M10-4/Fujitsu
M10-4S/SPARC
M10-4/SPARC
M10-4S
Service
Manual
・
February
2014
146
Содержание SPARC M10-4
Страница 20: ...Fujitsu M10 4 Fujitsu M10 4S SPARC M10 4 SPARC M10 4S Service Manual February 2014 xx ...
Страница 34: ...Fujitsu M10 4 Fujitsu M10 4S SPARC M10 4 SPARC M10 4S Service Manual February 2014 10 ...
Страница 49: ...A Figure 2 12 Location of system locator SPARC M10 4 M10 4S Chapter 2 Understanding the System Components 25 ...
Страница 56: ...Fujitsu M10 4 Fujitsu M10 4S SPARC M10 4 SPARC M10 4S Service Manual February 2014 32 ...
Страница 94: ...Fujitsu M10 4 Fujitsu M10 4S SPARC M10 4 SPARC M10 4S Service Manual February 2014 70 ...
Страница 110: ...Fujitsu M10 4 Fujitsu M10 4S SPARC M10 4 SPARC M10 4S Service Manual February 2014 86 ...
Страница 212: ...4 Close the rack door Fujitsu M10 4 Fujitsu M10 4S SPARC M10 4 SPARC M10 4S Service Manual February 2014 188 ...
Страница 246: ...4 Close the rack door Fujitsu M10 4 Fujitsu M10 4S SPARC M10 4 SPARC M10 4S Service Manual February 2014 222 ...
Страница 264: ...Fujitsu M10 4 Fujitsu M10 4S SPARC M10 4 SPARC M10 4S Service Manual February 2014 240 ...
Страница 290: ...Fujitsu M10 4 Fujitsu M10 4S SPARC M10 4 SPARC M10 4S Service Manual February 2014 266 ...
Страница 306: ...Fujitsu M10 4 Fujitsu M10 4S SPARC M10 4 SPARC M10 4S Service Manual February 2014 282 ...
Страница 328: ...Fujitsu M10 4 Fujitsu M10 4S SPARC M10 4 SPARC M10 4S Service Manual February 2014 304 ...
Страница 338: ...Fujitsu M10 4 Fujitsu M10 4S SPARC M10 4 SPARC M10 4S Service Manual February 2014 314 ...
Страница 382: ...Fujitsu M10 4 Fujitsu M10 4S SPARC M10 4 SPARC M10 4S Service Manual February 2014 358 ...
Страница 394: ...Fujitsu M10 4 Fujitsu M10 4S SPARC M10 4 SPARC M10 4S Service Manual February 2014 370 ...
Страница 416: ...Fujitsu M10 4 Fujitsu M10 4S SPARC M10 4 SPARC M10 4S Service Manual February 2014 392 ...
Страница 440: ...Fujitsu M10 4 Fujitsu M10 4S SPARC M10 4 SPARC M10 4S Service Manual February 2014 416 ...
Страница 459: ...Figure 28 22 Removing the cable cable PWR Chapter 28 Maintaining the Cable Kit of the Crossbar Box 435 ...
Страница 465: ...Figure 28 28 Securing the cable cable PWR Chapter 28 Maintaining the Cable Kit of the Crossbar Box 441 ...
Страница 468: ...Fujitsu M10 4 Fujitsu M10 4S SPARC M10 4 SPARC M10 4S Service Manual February 2014 444 ...
Страница 480: ...Fujitsu M10 4 Fujitsu M10 4S SPARC M10 4 SPARC M10 4S Service Manual February 2014 456 ...