40
SPARC Enterprise T5440 Server Product Notes • December 2010
After a Host Power-On Instruction Is Executed
from ILOM, the POST May Not Start, and
Processing May Not Go to OS Boot Processing or
the
ok
Prompt (CR 6752910)
After a host power-on instruction is executed from ILOM, the POST (self-diagnostics
test) may not start, and processing may not go to OS boot processing or the
ok
Prompt for OpenBoot PROM (OBP).
[ILOM command interface operation example]
[ALOM CMT compatibility shell operation example]
6940465
When the power supply temporarily suspended
due to events such as power failure, the message
as below may be displayed in the ILOM event
log.
2410 Wed Mar 31 04:06:49 2010
Chassis Log major
Mar 31 04:06:49 ERROR: [CMPx
] Received Fatal Error
The error detecting point may be [ZAMx ] in
some cases.
None.
After the power supply recovered, use the ILOM
CLI interface and execute the
show faulty
command. When there is no hardware error
output, this message can be safely ignored.
6659980
When you restarted Solaris OS, OpenBoot
PROM may output the error message "
ERROR:
Unable to disown USB port 3
."
“When You Restarted Solaris OS,
OpenBoot PROM May Output the Error
Message (CR 6659980)” on page 45
None.
This message has no impact on the system and
the USB device, and can be safely ignored.
->
start /SYS
->
start /SP/console
Are you sure you want to start /SP/console (y/n)?
y
Serial console started. To stop, type #.
sc>
poweron
sc>
console
Enter #. to return to ALOM.
TABLE 3-4
ILOM Issues
(Continued)
CR ID
Description
Workaround
Содержание SPARC Enterprise T5440 Server
Страница 4: ......
Страница 18: ...8 SPARC Enterprise T5440 Server Product Notes December 2010 ...
Страница 38: ...28 SPARC Enterprise T5440 Server Product Notes December 2010 ...
Страница 58: ...48 SPARC Enterprise T5440 Server Product Notes December 2010 ...
Страница 66: ...56 SPARC Enterprise T5440 Server Product Notes December 2010 ...
Страница 92: ...82 SPARC Enterprise T5440 Server Product Notes December 2010 ...