
Servicing Customer-Replaceable Units
105
▼
Remove FB-DIMMs
Before you begin, complete these tasks:
■
Read the section,
“Safety Information” on page 59
■
Power off the server, using one of the methods described in the section,
.
■
“Extend the Server to the Maintenance Position” on page 66
■
“Perform Electrostatic Discharge – Antistatic Prevention Measures” on page 69
■
“Remove the Top Cover” on page 69
■
“Remove a CMP/Memory Module” on page 99
Do the following:
1. If you are removing a faulty FB-DIMM, determine which FB-DIMM you want
to remove.
a. Press the FB-DIMM fault button.
See
“FB-DIMM Fault Button Locations” on page 113
.
b. Note which FB-DIMM fault LED is illuminated.
2. Push down on the ejector tabs on each side of the FB-DIMM until the
FB-DIMM is released.
Caution –
FB-DIMMs might be hot. Use caution when servicing FB-DIMMs.
3. Grasp the top corners of the faulty FB-DIMM and remove it from the
CMP/memory module.
4. Place the FB-DIMM on an antistatic mat.
5. Repeat
through
to remove any additional FB-DIMMs.
▼
Install FB-DIMMs
1. Unpackage the replacement FB-DIMMs and place them on an antistatic mat.
Tip –
See
“Supported FB-DIMM Configurations” on page 110
for information about
configuring the FB-DIMMs.
2. Ensure that the ejector tabs are in the open position.
Содержание SPARC Enterprise T5440 Server
Страница 1: ......
Страница 2: ......
Страница 6: ......
Страница 14: ...xii SPARC Enterprise T5440 Server Service Manual July 2009 Field Replaceable Units 176 Index 179 ...
Страница 26: ...xxiv SPARC Enterprise T5440 Server Service Manual July 2009 ...
Страница 84: ...58 SPARC Enterprise T5440 Server Service Manual July 2009 ...
Страница 180: ...154 SPARC Enterprise T5440 Server Service Manual July 2009 ...
Страница 192: ...166 SPARC Enterprise T5440 Server Service Manual July 2009 ...
Страница 198: ...172 SPARC Enterprise T5440 Server Service Manual July 2009 ...
Страница 212: ...186 SPARC Enterprise T5440 Server Service Manual July 2009 ...
Страница 213: ......
Страница 214: ......