Servicing Customer-Replaceable Units
85
See
TABLE: Fan Tray Fault LED on page 85
for a description of fan tray Fault LED
and its function.
The front panel Fan Fault LED, and the front and rear panel Service Required LEDs
are also lit if the system detects a fan tray fault. In addition, the system Overtemp
LED might be lit if a fan fault causes an increase in system operating temperature.
See
and
for more
information about system status LEDs.
Related Information
■
■
“Hot-Pluggable and Hot-Swappable Devices” on page 72
■
“Fan Tray Fault LED” on page 84
Servicing Power Supplies
The server is equipped with redundant hot-swappable power supplies. Redundant
power supplies enable you to remove and replace a power supply without shutting
the server down, provided that at least two other power supplies are online and
working.
Note –
If a power supply fails and you do not have a replacement available, leave
the failed power supply installed to ensure proper airflow in the server.
Related Information
■
“Identifying Server Components” on page 1
■
■
“Hot-Pluggable and Hot-Swappable Devices” on page 72
■
“Power Supply Device Identifiers” on page 91
TABLE:
Fan Tray Fault LED
LED
Color
Notes
Fault
Amber
This LED is lit when the fan tray is faulty.
Содержание SPARC Enterprise T5440 Server
Страница 1: ......
Страница 2: ......
Страница 6: ......
Страница 14: ...xii SPARC Enterprise T5440 Server Service Manual July 2009 Field Replaceable Units 176 Index 179 ...
Страница 26: ...xxiv SPARC Enterprise T5440 Server Service Manual July 2009 ...
Страница 84: ...58 SPARC Enterprise T5440 Server Service Manual July 2009 ...
Страница 180: ...154 SPARC Enterprise T5440 Server Service Manual July 2009 ...
Страница 192: ...166 SPARC Enterprise T5440 Server Service Manual July 2009 ...
Страница 198: ...172 SPARC Enterprise T5440 Server Service Manual July 2009 ...
Страница 212: ...186 SPARC Enterprise T5440 Server Service Manual July 2009 ...
Страница 213: ......
Страница 214: ......