Chapter 3
Known Issues
45
According to the IPMI PET Warning and SNMP
Trap Warning Settings in the Warning Rule
Settings, Warning Message Creation may not be
Possible Depending on the Event Type (CR
6746677)
According to the IPMI PET warning and SNMP trap warning settings in the warning
rule settings, warning message creation may not be possible depending on the event
type, irrespective of the warning level.
Execution example:
■
"/SYS/MB/component name Disabled by CLI action." or "/SYS/MB/component
name Disabled by user" (critical) is reported with an IPMI PET warning when a
component is disabled by the
set /SYS/
component-name
component_state=
disabled
command or
disablecomponent
command, respectively.
■
"Host has been powered on" (major) is not reported with an IPMI PET warning or
SNMP trap warning when the power to the host is turned on.
■
"/SYS/MB/FT* has exceeded low non-recoverable threshold." (critical) is not
reported when the fan speed of a built-in fan falls below the threshold value.
■
"ERROR: POST errors detected" (major) is not reported with an IPMI PET
warning or SNMP trap warning when an error is detected in a POST (self-
diagnostics test).