Error Messages from the Ultra320 SCSI Card
At the time of boot from a device connected with the dual-channel Ultra320 SCSI
Card (SE0X7SC2F, SE0X7SC2X), the following messages may be displayed. Since
these messages do not have an effect on your system behavior, ignore these
messages.
Erroneous Power Supply Faults (CR 6614432)
Some SPARC Enterprise T5120 servers report a low AC line input voltage fault when
the input voltage is in the range of 90V to 94V AC. This is not the correct threshold
and should not indicate an AC input fault until the voltage drops below 90V AC.
Example of erroneous fault messages:
EXT3-fs warning: maximal mount count reached, running e2fsck is
recommended
EXT3 FS 2.4-0.9.19, 19 August 2002 on tffs(100,1), internal journal
EXT3-fs: mounted filesystem with ordered data mode.
kjournald starting. Commit interval 5 seconds
EXT3-fs warning: maximal mount count reached, running e2fsck is
recommended
...
ipt_recent v0.3.1: ... < ... >. http://snowman.net/projects/ipt_recent/
arp_tables: (C) 2002
802.1Q VLAN Support v1.8 ... < ... >
All bugs added by ...
SCSI command timeout occurred
SCSI interrupts not occur
sc>
showlogs
Oct 09 14:13:17: Chassis |major : "Host is running"
Oct 09 14:36:10: IPMI |minor : "ID = 264 : 10/09/2007 : 14:36:10 : Power
Supply : /PS1/DC_POK : State Deasserted"
Oct 09 14:36:11: IPMI |minor : "ID = 265 : 10/09/2007 : 14:36:11 : Power
Supply : /PS1/AC_POK : State Deasserted"
Oct 09 14:36:14: IPMI |minor : "ID = 266 : 10/09/2007 : 14:36:14 : Power
Supply : /PS1/FAIL : State Asserted"
Содержание SPARC Enterprise T5120
Страница 10: ...x SPARC Enterprise T5120 and T5220 Servers Product Notes April 2010 ...
Страница 20: ...8 SPARC Enterprise T5120 and T5220 Servers Product Notes April 2010 ...
Страница 84: ...72 SPARC Enterprise T5120 and T5220 Servers Product Notes April 2010 ...
Страница 149: ......
Страница 150: ......