Chapter 4
Replacing Hot-Swappable and Hot-Pluggable FRUs
4-5
FIGURE 4-2
Locating Power Supplies and Release Latch
2. At the
sc>
prompt, issue the
removefru
command.
The
removefru
command indicates if it is OK to perform a hot-swap of a power
supply. This command does not perform any action, but provides a warning if the
power supply should not be removed because the other power supply is not
providing power to the server.
Example:
In this command,
PS
n
is the power supply identifier for the power supply you plan
to remove, either
PS0
or
PS1
.
3. Gain access to the rear of the server where the faulty power supply is located.
4. At the rear of the server, release the cable management arm (CMA) tab (
)
and swing the CMA out of the way so you can access the power supply.
sc>
removefru PS
n
Are you sure you want to remove PS0 [y/n]?
y
<PS
n
> is safe to remove.
PS1
PS0
Latches
Содержание SPARC Enterprise T2000
Страница 1: ......
Страница 2: ......
Страница 6: ......
Страница 16: ...xiv SPARC Enterprise T2000 Server Service Manual April 2007 ...
Страница 18: ...xvi SPARC Enterprise T2000 Server Service Manual April 2007 ...
Страница 27: ...Preface xxv Reader s Comment Form ...
Страница 43: ...Chapter 3 Server Diagnostics 3 3 FIGURE 3 1 Diagnostic Flow Chart flowchart ...
Страница 69: ...Chapter 3 Server Diagnostics 3 29 FIGURE 3 10 Flowchart of ALOM CMT Variables for POST Configuration ...
Страница 106: ...4 12 SPARC Enterprise T2000 Server Service Manual April 2007 ...
Страница 152: ...5 46 SPARC Enterprise T2000 Server Service Manual April 2007 ...
Страница 163: ...Appendix A Field Replaceable Units A 3 FIGURE A 2 Field Replaceable Units 2 of 2 13 11 12 10 14 16 15 ...
Страница 173: ......
Страница 174: ......