Chapter 1
Preparing for Installation
3
Caution –
To protect electronic components from electrostatic damage, which can
permanently disable the system or require repair by service technicians, place
components on an antistatic surface, such as an antistatic discharge mat, an antistatic
bag, or a disposable antistatic mat. Wear an antistatic grounding strap connected to
a metal surface on the chassis when you work on system components.
Installation Overview
This installation guide provides procedures which are to be performed in the
following order.
1. Verify that you have received all of the components that ship with your server.
2. Gather configuration information for your system. See your system administrator
for specific details, including these parameters:
■
Netmask
■
IP address for the system controller
■
Gateway IP address
3. Install any optional components shipped with your system. If you have
purchased other optional components such as additional memory, install them
prior to mounting the server in a rack. See
“Optional Component Installation” on
4. Mount the server into a rack or cabinet. See
“Installing the Server in a Rack” on
.
Note –
In the rest of this manual, the term
rack
means either an open rack or a
closed cabinet.
5. Connect the server to a serial terminal or a terminal emulator (PC or workstation)
to display system messages. See
“Powering On the System for the First Time” on
Tip –
The serial terminal or a terminal emulator should be connected before you
connect the power cables. As soon as AC power is connected to the system, the
system controller immediately powers on and runs diagnostics. Diagnostic test
failures will be printed on the serial terminal. For more information, refer to the
Advanced Lights Out Management (ALOM) CMT 1.x Guide
.
Содержание SPARC Enterprise T2000
Страница 1: ......
Страница 2: ......
Страница 6: ......
Страница 10: ...viii SPARC Enterprise T2000 Server Installation Guide April 2007 ...
Страница 14: ...xii SPARC Enterprise T2000 Server Installation Guide April 2007 ...
Страница 24: ...xxii SPARC Enterprise T2000 Server Installation Guide April 2007 Reader s Comment Form ...
Страница 26: ...xxiv SPARC Enterprise T2000 Server Installation Guide April 2007 ...
Страница 35: ...Chapter 1 Preparing for Installation 9 FIGURE 1 5 Locating the Locks on the Slide Rail Assembly ...
Страница 76: ...50 SPARC Enterprise T2000 Server Installation Guide April 2007 ...
Страница 86: ...60 SPARC Enterprise T2000 Server Installation Guide April 2007 ...
Страница 87: ......
Страница 88: ......