14
U41161-J-Z126-1-76
Control panel on the S140 Business Server cabinet
Controls and indicators
4.1 Control panel on the S140 Business Server cabinet
The control panel is connected with the service processor (SVP) in the S140 Business
Server. The physical structure of the control panel is illustrated in the following diagram:
Figure 5: Control panel on the cabinet of the S140 Business Server
The functions of the indicators and control elements on the control panel are described
below.
4.1.1
Function of the indicators
STATUS
The STATUS indicator is an LCD display and can show alphanumeric characters. The
codes change when the Business Server and the IMPL are switched on. No P codes
should be displayed if POWER ON or IMPL has been run without errors (see next
page). If this is not the case, this indicates a malfunction and you should contact the
service department.
STATUS
LCD BACK LIGHT
POWER CONTROL
ALARM STOP
CANCEL/
POWER ON
STAND-BY
POWER
COMPLETE
SYSTEM
CHECK
IMPL