![Fujitsu ROG07KPCA Скачать руководство пользователя страница 96](http://html.mh-extra.com/html/fujitsu/rog07kpca/rog07kpca_service-manual_2343973096.webp)
1-3. Dry operation
The rotation number of compressor shall change according to the temperature, set temperature, and
room temperature variation which the room temperature sensor of the indoor unit has detected as
shown in the table below.
Zone is defined by set temperature and room temperature.
•
Rotation number range of compressor
Unit: rps
Model name
Outdoor temperature zone
Operating frequency
RSG07KPCE
RSG09KPCE
RSG12KPCE
X zone
24
J zone
18
Y zone
0
•
Compressor control based on room temperature
Ts+0.5°C
Ts -1.5
°C
Ts-0.5
°C
Ts+1.5
°C
X zone
J zone
Y zone
Room temperature drops
Room temperature rises
Ts: Set temperature
1-4. Rotation number of compressor at normal start-up
¢
Models: ROG07KPCA, ROG09KPCA, and ROG12KPCA
Rotation number of compressor soon after starting is controlled as below.
Rotation number I
Rotation number II
Rotation number III
Rotation number IV
Rotation number V
Rotation number VI
Rotation number VII
Time 1
Time 2
Time 3
Time 4
Time 5
Time 6
Time 7
Rotation number (rps)
I
II
III
IV
V
VI
VII
45
56
68
77
84
93
103
Time (sec)
1
2
3
4
5
6
7
60
140
170
220
280
360
430
1-3. Dry operation
- (04-4) -
1. Rotation number control of compressor
CONTROL AND
FUNCTIONS
CONTROL AND
FUNCTIONS
Содержание ROG07KPCA
Страница 4: ......
Страница 5: ...1 GENERAL INFORMATION 2021 12 16 SR_CH01_AS059EJ_01 ...
Страница 13: ...2 TECHNICAL DATA AND PARTS LIST 2021 12 16 SR_CH02_AS059EJ_01 ...
Страница 31: ...3 TROUBLESHOOTING 2021 12 16 SR_CH03_AS059EJ_01 ...
Страница 34: ......
Страница 91: ...4 CONTROL AND FUNCTIONS 2021 12 16 SR_CH04_AS059EJ_01 ...
Страница 123: ...5 FILED WORKING 2021 12 16 SR_CH05_AS059EJ_01 ...