Service Supplement TX600 S3
27
Replacement routines
Replacing the LocalView module
4.4
Replacing the LocalView module
I
The LocalView module is used exclusively in the rack model.
It is delivered in a module frame which engages in the bay. The engage-
ment lock must therefore be pressed for removal of the module frame.
Requirements
–
The server has been switched off
–
The power cables have been uplugged
–
Rack model only: The server has been pulled out
–
The housing cover has been removed
–
The CD/DVD drive has been removed (see Options Guide)
Removing the LocalView module
Ê
For easier access, unplug the cables to the control panel and the control
panel board from the SCSI backplane.
Figure 10: Removing the LocalView module
Ê
Remove the connection cable (4-pin I
2
C bus cable) which leads to the
LocalView module from the SCSI backplane (A) and the chassis ID module
(see
A
B
LocalView module