Hardware Installation
Installing/Removing the Rack Model into the Rack
4.4
Installing/Removing the Rack Model into
the Rack
V
CAUTION!
●
Please observe the safety notes and notes on mounting into the rack
in chapter “Important Notes” on page 13.
●
At least two people are needed to position the server into/out of the
rack.
●
The rack can tip over when more than one unit is pulled out.
●
The server may not occupy the top height unit of the rack (42 HU
Classic Rack, 38 HU/42 HU PRIMECENTER Rack and/or
DataCenter Rack), as otherwise no board and/or system fan can be
replaced even with the unit pulled out completely.
Requirements of the rack
The rack systems of the Fujitsu Siemens Computers GmbH (PRIMECENTER
Rack; DataCenter Rack and 19-Inch (Classic) Rack) support fully the instal-
lation of the PRIMERGY server systems. The installation into the at present
usual rack systems of different foreign manufacturers (3rd-Party Rack) is
supported to large part.
To accommodate the ventilation concept and ensure proper ventilation of the
components in the rack, any unused areas must be closed using dummy covers.
The power is supplied via the socket strips available in the rack.
The main features of the rack systems of the Fujitsu Siemens Computers are:
PRIMECENTER Rack
–
Frontally bolted telescopic rails or sliding rails.
The rails are provided with a linear alignment possibility to ensure also an
adjustment to different rack depths.
–
Extended cable management within the lateral rack area.