Release the locking bars on both rack rails (1).
▶
Lift up the front of the server as shown so that the front and middle rack
mounting bolts are disengaged from the mounting points on the rack rails
(2).
▶
Lift the server out of the rear mounting points (3) and place it on an even
surface.
4.4.2.3
Removing the top cover
Figure 5: Removing the top cover (rack model)
▶
Open the locking lever (1). This will push the top cover back disengaging the
locking mechanism (2).
Basic hardware procedures
TX2550 M5
Upgrade and Maintenance Manual
55