Figure 92: Installing the 3.5-inch HDD module
▶
Insert the HDD module into a drive bay and carefully push back as far as it
will go (1).
▶
Close the locking lever to lock the HDD module in place (2).
▶
When using a RAID array, add the additional HDD to the RAID array.
Configuring the RAID array, refer to the documentation of the RAID
controller, used in your configuration, see
Concluding steps
▶
When working on a floorstand model, close the HDD bay cover, see
"Installing the accessible drive bay cover" on page 78
7.4.5
Removing 3.5-inch HDD modules
Customer Replaceable
Unit (CRU)
Hardware: 5 minutes
Tools:
tool-less
Hard disk drive (HDD) / solid state disk (SSD)
TX2550 M5
Upgrade and Maintenance Manual
179