Select the status menu of the desired component:
▶
Select
CPU Status
for CPUs.
This option is only available for multi-processor systems.
▶
Select
Memory Status
for memory modules.
▶
Select
PCI Status
for expansion cards.
▶
Reset replaced components to
Enable
.
▶
Save your changes and exit the BIOS.
For more information on how to access the BIOS and modify settings,
see the corresponding BIOS Setup Utility reference manual.
5.3.10
Verifying the memory mode
If a memory module fails, the server will reboot and the defective module will
be disabled. As a result, the current operation mode (e.g. Mirrored Channel
mode) may no longer be available due to a lack of identical memory module
pairs. In this case, the operation mode will automatically revert to Independent
Channel Mode.
For more information on memory operation modes available for your
server, see
"Modes of operation" on page 396
After replacing the defective module(s) the memory operation mode is
automatically reset to its original state. It is recommended to verify that the
operation mode has been correctly.
▶
Enter the BIOS.
▶
Select the
Advanced
menu.
▶
Select
Memory Status
and verify that none of the memory modules are
marked as
Failed
.
▶
Select
Memory Configuration
to verify
Memory Mode of Operation
.
▶
Save your changes (if applicable) and exit the BIOS.
Basic software procedures
TX2550 M5
Upgrade and Maintenance Manual
125
Содержание PRIMERGY TX2550 M5
Страница 20: ...Content Upgrade and Maintenance Manual TX2550 M5 ...
Страница 106: ...Basic hardware procedures 106 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 322: ...Fans 322 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 392: ...Expansion cards and backup units 392 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 408: ...Main memory 408 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 428: ...Processor CPU 428 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 522: ...System board and components 522 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 590: ...FUJITSU Server PRIMERGY TX2550 M5 System Cabling Overview System Cabling Overview English Cable plan for May 2019 ...
Страница 631: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...