86
Operating Manual
TX2550 M5
Operation
6.4
Installing a second PSU
6.4.1
Removing the dummy cover
Figure 26: Removing the PSU dummy cover
Ê
Press in on both release latches (1) and remove the dummy cover (2).
V
CAUTION!
Keep the dummy cover for future use. If a PSU is removed and not
immediately replaced by a new one, a dummy cover must be installed in
the bay again to comply with applicable EMC regulations and satisfy
cooling requirements.
6.4.2
Installing a PSU
Figure 27: Folding up the handle
Ê
Push the handle of the PSU halfway upward in the direction of the arrow.