TX2550 M5
Operating Manual
67
Starting up
5.5
Connecting cables
5.5.1
Notes on connecting/disconnecting cables
V
CAUTION!
Always read the documentation supplied with the device you wish to
connect.
Never connect, or disconnect cables during a thunderstorm.
Never pull on a cable when disconnecting it. Always take hold of the
cable by the plug.
Follow the sequence described below to connect or disconnect external
devices to or from the server:
Ensure that you wait for 10 seconds or more after shutdown before
turning the server on.
Connecting cables
Ê
Switch off the server and equipment switches.
Ê
Disconnect all power cords from the properly grounded power outlets.
Ê
Connect all cables to the server and peripherals.
Ê
Connect all data communication cables into the utility sockets.
Ê
Connect all power cords into the properly grounded power outlets.
Disconnecting cables
Ê
Switch off the server and equipment switches.
Ê
Disconnect all power cords from the properly grounded power outlets.
Ê
Disconnect all data communication cables from the utility sockets.
Ê
Disconnect the relevant cables from the server and all the peripherals.
I
For connecting or disconnecting LAN cables, the server does not need
to be powered off. To avoid loss of data teaming function has to be
enabled.
Содержание PRIMERGY TX2550 M5
Страница 1: ...Operating Manual English FUJITSU Server PRIMERGY TX2550 M5 Operating Manual May 2019 ...
Страница 6: ...Operating Manual TX2550 M5 ...
Страница 10: ...Operating Manual TX2550 M5 Content ...
Страница 12: ...12 Operating Manual TX2550 M5 Introduction ...
Страница 16: ...16 Operating Manual TX2550 M5 Before you start ...
Страница 42: ...42 Operating Manual TX2550 M5 Product description ...
Страница 56: ...56 Operating Manual TX2550 M5 Important information ...
Страница 96: ...96 Operating Manual TX2550 M5 Troubleshooting and tips ...
Страница 106: ...106 Operating Manual TX2550 M5 Warranty and service ...