
184
Upgrade and Maintenance Manual
TX2550 M4
Hard disk drive (HDD) / solid state drive (SSD)
7.3.9
Replacing a 2.5-inch HDD/SSD module
I
PCIe SSDs SFF are mounted in the same frames as the 2.5-inch
HDD/SSD modules. Therefore, this section is also valid and applicable if
PCIe SSDs SFF are used.
V
CAUTION!
●
Only remove an HDD/SSD module during operation if the drive is not
currently being accessed. Observe the indicators for the
corresponding HDD/SSD modules, see section
hot-plug HDD/SSD module" on page 506
●
An HDD/SSD module can be replaced while the system is in
operation.
RAID configuration with a RAID controller:
Modular Host Bus Adapter with "Integrated RAID" (IR). RAID levels 0
and 1 are supported for internal HDD configurations.
– Modular RAID 0/1 controller with "MegaRAID functionality"
(integrated MegaRAID). RAID levels 0, 1,10,5 and 50 are
supported for internal HDD configurations.
– Modular RAID 5/6 controller with "MegaRAID functionality"
(MegaRAID). RAID levels 0, 1, 10, 5, 50, 6 and 60 are supported
for internal HDD configurations. As an option, a flash backup unit
(FBU) can save the memory content even if the power fails.
Cache memory size of up to 8 GB is available.
RAID configuration without a RAID controller:
Please follow the instruction of each software e.g. VSAN, Storage
Spaces, and Storage Spaces Direct, provided separately to use the
software RAID function of OS or Hypervisor.
●
All HDD/SSD modules (drives) must be uniquely identified so that
they can be reinstalled in their original bays later. If this is not done,
existing data can be lost.
Customer Replaceable Unit
(CRU)
Hardware:
5 minutes
Tools:
Phillips PH1 / (+) No. 1 screw driver (for installation frame)
Содержание PRIMERGY TX2550 M4
Страница 6: ...Upgrade and Maintenance Manual TX2550 M4 ...
Страница 36: ...36 Upgrade and Maintenance Manual TX2550 M4 Before you start ...
Страница 104: ...104 Upgrade and Maintenance Manual TX2550 M4 Basic hardware procedures ...
Страница 136: ...136 Upgrade and Maintenance Manual TX2550 M4 Basic software procedures ...
Страница 284: ...284 Upgrade and Maintenance Manual TX2550 M4 Hard disk drive HDD solid state drive SSD ...
Страница 372: ...372 Upgrade and Maintenance Manual TX2550 M4 Processor CPU ...
Страница 458: ...458 Upgrade and Maintenance Manual TX2550 M4 System board and components ...
Страница 480: ...480 Upgrade and Maintenance Manual TX2550 M4 Converting a floorstand model to a rack model ...
Страница 491: ...TX2550 M4 Upgrade and Maintenance Manual 491 18 Appendix A 18 1 Mechanical overview 18 1 1 Server front ...
Страница 516: ...516 Upgrade and Maintenance Manual TX2550 M4 Appendix A ...
Страница 518: ...518 Upgrade and Maintenance Manual TX2550 M4 Appendix B ...
Страница 519: ...FUJITSU Server PRIMERGY TX2550 M4 System Cabling Overview System Cabling Overview English Cable plan for April 2018 ...
Страница 558: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan January 2017 ...