122
Upgrade and Maintenance Manual
TX2550 M4
Basic software procedures
Ê
Enter the BIOS.
Ê
Select the
Advanced
menu.
Ê
Select the status menu of the desired component:
– CPUs:
CPU Status
I
This option is only available for multi-processor systems.
– Memory:
Memory Status
– Expansion cards:
PCI Status
Ê
Reset replaced components to
Enable
.
Ê
Save your changes and exit the BIOS.
I
For more information on how to access the BIOS and modify settings,
see the corresponding BIOS Setup Utility reference manual.
5.2.10 Verifying the memory mode
If a memory module fails, the server will reboot and the defective module will be
disabled. As a result, the current operation mode (e.g. Mirrored Channel mode)
may no longer be available due to a lack of identical memory module pairs. In
this case, the operation mode will automatically revert to Independent Channel
Mode.
I
For more information on memory operation modes available for your
server, see section
"Modes of operation" on page 349
After replacing the defective module(s) the memory operation mode is
automatically reset to its original state. It is recommended to verify that the
operation mode has been correctly.
Ê
Enter the BIOS.
Ê
Select the
Advanced
menu.
Ê
Select
Memory Status
and verify that none of the memory modules are
marked as
Failed
.
Ê
Select
Memory Configuration
to verify
Memory Mode of Operation
.
Ê
Save your changes (if applicable) and exit the BIOS.
I
For more information on how to access the BIOS and modify settings,
see the corresponding BIOS Setup Utility reference manual.
Содержание PRIMERGY TX2550 M4
Страница 6: ...Upgrade and Maintenance Manual TX2550 M4 ...
Страница 36: ...36 Upgrade and Maintenance Manual TX2550 M4 Before you start ...
Страница 104: ...104 Upgrade and Maintenance Manual TX2550 M4 Basic hardware procedures ...
Страница 136: ...136 Upgrade and Maintenance Manual TX2550 M4 Basic software procedures ...
Страница 284: ...284 Upgrade and Maintenance Manual TX2550 M4 Hard disk drive HDD solid state drive SSD ...
Страница 372: ...372 Upgrade and Maintenance Manual TX2550 M4 Processor CPU ...
Страница 458: ...458 Upgrade and Maintenance Manual TX2550 M4 System board and components ...
Страница 480: ...480 Upgrade and Maintenance Manual TX2550 M4 Converting a floorstand model to a rack model ...
Страница 491: ...TX2550 M4 Upgrade and Maintenance Manual 491 18 Appendix A 18 1 Mechanical overview 18 1 1 Server front ...
Страница 516: ...516 Upgrade and Maintenance Manual TX2550 M4 Appendix A ...
Страница 518: ...518 Upgrade and Maintenance Manual TX2550 M4 Appendix B ...
Страница 519: ...FUJITSU Server PRIMERGY TX2550 M4 System Cabling Overview System Cabling Overview English Cable plan for April 2018 ...
Страница 558: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan January 2017 ...