After replacing a network controller or the system board, switch on and boot
the server, see
"Switching on the server" on page 60
The hardware configuration tool for Red Hat Linux, will launch at boot and
detect the new and/or changed hardware on your system.
▶
For the changes to take effect, you need to reboot the network by entering
the following command:
# service network restart
If the system board or network controller offers multiple LAN ports, it
is necessary to update the remaining
ifcfg-eth<x>
definition files
accordingly.
▶
Update the NIC configuration file to reflect the new card sequence and MAC
address.
5.3.12 Resuming BitLocker functionality
If BitLocker Drive Encryption has been suspended for maintenance purposes
(see
"Suspending BitLocker functionality" on page 71
to complete the service task.
▶
If applicable, ask the system administrator to enter the recovery key in order
to boot the OS.
If BitLocker Drive Encryption has been suspended prior to replacing
components you won't be asked for a recovery key when rebooting
the server after the maintenance task. However, if BitLocker
functionality has not been suspended, Windows will enter recovery
mode and ask you to input recovery key for further booting.
▶
Ask the system administrator to enable the previously suspended BitLocker
protection on the system volume, using the
BitLocker Drive Encryption
control panel item:
▶
Click
Start
-
Control Panel
-
System and Security
-
BitLocker Drive
Encryption
to open the BitLocker Drive Encryption.
▶
Select the system volume, and click
Resume Protection
.
Basic software procedures
TX1320 M5
Upgrade and Maintenance Manual
91
Содержание PRIMERGY TX1320 M5
Страница 70: ...Basic hardware procedures 70 Upgrade and Maintenance Manual TX1320 M5 ...
Страница 126: ...Figure 48 Removing the power distribution board A Power supply unit PSU 126 Upgrade and Maintenance Manual TX1320 M5 ...
Страница 132: ...Power supply unit PSU 132 Upgrade and Maintenance Manual TX1320 M5 ...
Страница 179: ... Switching on the server on page 60 Performing a fan test on page 100 Fans TX1320 M5 Upgrade and Maintenance Manual 179 ...
Страница 180: ...Fans 180 Upgrade and Maintenance Manual TX1320 M5 ...
Страница 266: ...Accessible drives 266 Upgrade and Maintenance Manual TX1320 M5 ...
Страница 272: ...Front panel 272 Upgrade and Maintenance Manual TX1320 M5 ...
Страница 280: ...Front USB connector 280 Upgrade and Maintenance Manual TX1320 M5 ...
Страница 298: ...Dust cover 298 Upgrade and Maintenance Manual TX1320 M5 ...
Страница 346: ...System board and components 346 Upgrade and Maintenance Manual TX1320 M5 ...
Страница 376: ...FUJITSU Server PRIMERGY TX1320 M5 Reference Manual Reference Manual English Cable Plan for October 2021 ...
Страница 402: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...