For more information on iRMC settings, see the iRMC user guides.
5.3.8
Enabling replaced components in the BIOS
When a CPU, an expansion card, or a memory module fails, the defective
component will be set to
Disabled
or
Failed
in the BIOS. The server will then
reboot with only the intact hardware components remaining in the system
configuration. After replacing the defective component, it needs to be
reenabled in the BIOS.
▶
Enter the BIOS.
▶
Select the
Advanced
menu.
▶
Select the status menu of the desired component:
▶
Select
CPU Status
for CPUs.
This option is only available for multi-processor systems.
▶
Select
Memory Status
for memory modules.
▶
Select
PCI Status
for expansion cards.
▶
Reset replaced components to
Enable
.
▶
Save your changes and exit the BIOS.
For more information on how to access the BIOS and modify settings,
see the corresponding BIOS Setup Utility reference manual.
5.3.9
Verifying the system time settings
This task only applies to Linux and VMware environments.
After the system board has been replaced, the system time is set automatically.
By default, the RTC (Real Time Clock) time standard is set as the local time.
Basic software procedures
TX1320 M5
Upgrade and Maintenance Manual
87
Содержание PRIMERGY TX1320 M5
Страница 70: ...Basic hardware procedures 70 Upgrade and Maintenance Manual TX1320 M5 ...
Страница 126: ...Figure 48 Removing the power distribution board A Power supply unit PSU 126 Upgrade and Maintenance Manual TX1320 M5 ...
Страница 132: ...Power supply unit PSU 132 Upgrade and Maintenance Manual TX1320 M5 ...
Страница 179: ... Switching on the server on page 60 Performing a fan test on page 100 Fans TX1320 M5 Upgrade and Maintenance Manual 179 ...
Страница 180: ...Fans 180 Upgrade and Maintenance Manual TX1320 M5 ...
Страница 266: ...Accessible drives 266 Upgrade and Maintenance Manual TX1320 M5 ...
Страница 272: ...Front panel 272 Upgrade and Maintenance Manual TX1320 M5 ...
Страница 280: ...Front USB connector 280 Upgrade and Maintenance Manual TX1320 M5 ...
Страница 298: ...Dust cover 298 Upgrade and Maintenance Manual TX1320 M5 ...
Страница 346: ...System board and components 346 Upgrade and Maintenance Manual TX1320 M5 ...
Страница 376: ...FUJITSU Server PRIMERGY TX1320 M5 Reference Manual Reference Manual English Cable Plan for October 2021 ...
Страница 402: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...