If a Linux/VMware OS is used and the hardware clock has been configured as
UTC (Universal Time, Coordinated) in the OS, the BMC local time may not be
mapped correctly.
▶
After replacing the system board, ask the system administrator whether the
RTC or UTC time standard is to be used as system time.
If the system time (RTC) is set to UTC, the SEL (System Event Log)
time stamps may differ from the local time.
▶
Enter the BIOS.
▶
Select the
Main
menu.
▶
Under
System Time
and
System Date
specify the correct time and date.
By default, the system time set in the BIOS is RTC (Real Time Clock)
local time. If your IT infrastructure relies on universally accepted time
standards, set the
System Time
to UTC (Universal Time,
Coordinated) instead. Greenwich Mean Time (GMT) can be
considered equivalent to UTC.
▶
Save your changes and exit the BIOS.
For more information on how to access the BIOS and modify settings,
see the corresponding BIOS Setup Utility reference manual.
5.2.5
Viewing the System Event Log (SEL)
▶
Enter the BIOS.
▶
Enter the
Event Logs
menu.
▶
Click
View Smbios Event Log
.
For detailed information on how to view the SEL using BIOS, see the
"BIOS Setup Utility" reference manual.
Basic software procedures
66
Upgrade and Maintenance Manual
TX1310 M5
Содержание PRIMERGY TX1310 M5
Страница 14: ...Content Upgrade and Maintenance Manual TX1310 M5 ...
Страница 80: ...Power supply unit PSU 80 Upgrade and Maintenance Manual TX1310 M5 ...
Страница 124: ...Expansion cards 124 Upgrade and Maintenance Manual TX1310 M5 ...
Страница 156: ...Processor CPU 156 Upgrade and Maintenance Manual TX1310 M5 ...
Страница 174: ...Front panel and front USB 174 Upgrade and Maintenance Manual TX1310 M5 ...
Страница 216: ...System board and components 216 Upgrade and Maintenance Manual TX1310 M5 ...
Страница 238: ...Appendix A 238 Upgrade and Maintenance Manual TX1310 M5 ...
Страница 240: ...FUJITSU Server PRIMERGY TX1310 M5 Reference Manual Reference Manual English Cable plan for March 2022 ...
Страница 257: ...List of all used screws for PRIMERGY Servers Assembled in WCZ and FIT July 2021 ...