Power supply unit (PSU)
6.2
Replacing the PSU
6.2.1
Preliminary steps
Ê
"Shutting down the server" on page 44
Ê
"Disconnecting the power cord" on page 45
Ê
"Getting access to the component" on page 46
Ê
"Extending the HDD cage out of the chassis" on page 47
6.2.2
Removing the PSU
I
You are advised to perform this routine with the server in a horizontal
position.
Ê
Push the backup drive somewhat to the front to get more space, see section
"Removing a backup drive" on page 169
Figure 23: Disconnecting power cable
Ê
Disconnect the power cable from system board connector "PWR12V".
Field Replaceable Unit
(FRU)
Hardware: 10 minutes
Tools:
Phillips PH2 / (+) No. 2 screw driver