9.2.2 Error Messages
POST Error Messages
This section explains error messages of Power On Self Test: a device check performed during the server
startup (POST).
If an error occurs during POST, the following messages are displayed.
`
When checking/changing the settings of the BIOS Setup Utility, refer to "8.2 BIOS Setup Utility"
(
`
For instructions on checking peripheral connections, refer to "Start Guide".
`
For details on installing internal options, refer to "Chapter 7 Installing Hardware Options" (
table: List of POST Errors
Message
Description
Failure Fixed Disk
IDE device error. Power off the server and turn it back on.
If the message still appears, the baseboard must be replaced.
Contact an office listed in the "Contact Information" of "Start
Guide".
Stuck Key
Keyboard error. Release any keys held down on the keyboard.
Check whether the keyboard is connected properly. If the
message still appears, the keyboard must be replaced.
Keyboard error
Keyboard controller error
Keyboard controller error. Release any keys held down on the
keyboard. Check whether the keyboard is connected properly.
If the message still appears, the baseboard must be replaced.
Contact an office listed in the "Contact Information" of "Start
Guide".
System RAM Failed at offset: ********h
A memory error has occurred. Turn the server off and check
that the memory modules are installed properly. If the message
appears even after the server is turned on again, check the error
log and replace the memory modules. If the message still
appears, the baseboard must be replaced. Contact an office
listed in the "Contact Information" of "Start Guide".
Shadow RAM Failed at offset: ********h
Extended RAM Failed at address line: ****h
Memory type mixing detected
The installation configuration of the memory is wrong. Verify
that the same types of memory modules are installed in the
slots of the same bank. If the message displays even though the
installation is correct, replace the memory module.
Memory decreases in Size
Memory error. Due to a memory failure, available memory
capacity is less than the capacity of the installed memory.
Check the error log and replace the faulty memory module. If
the message still appears after the replacement, the baseboard
must be replaced. Contact an office listed in the "Contact
Information" of "Start Guide".
Non Fujitsu Siemens Memory Module detected
- Warranty restricted!
Memory error. Check that the jumper pin settings and BIOS
Setup Utility settings are correct. If the message still appears,
the baseboard must be replaced. Contact an office listed in the
"Contact Information" of "Start Guide".
System battery is dead - Replace and run
SETUP
Battery error. Check whether the battery is installed correctly
on the baseboard. If the message still appears, the battery must
be replaced.
Содержание Primergy TX120
Страница 6: ...6 ...
Страница 12: ...12 ...
Страница 62: ...62 Chapter 3 OS Installation Using ServerStart 6 Set items and click Next The Network Protocol window appears ...
Страница 122: ...122 Chapter 4 Manual OS Installation ...
Страница 152: ...152 Chapter 5 Operations after OS Installation ...
Страница 188: ...188 Chapter 7 Installing Hardware Options ...
Страница 210: ...210 Chapter 8 Configuring Hardware and Utilities ...
Страница 262: ...262 ...