190
Chapter 8 Configuring Hardware and Utilities
8.1 Jumper Settings
The BIOS password setting can be deleted through the jumper settings.
`
Do not change the jumper settings in normal use.
Jumper Location
The jumper of the server is located on the baseboard as shown below.
Jumper Settings
To change the setting, set the jumper as follows:
Functions and settings of each jumper are as follows:
table: Jumper Settings
Jumper
Number
Function
Setting
Description
JP1
BIOS recovery
1-2 (standard)
Activates with the normal BIOS information.
2-3
Activates with the saved BIOS information.
JP2
BIOS password
recovery
1-2
Disables the BIOS password.
2-3 (standard)
Enables the BIOS password.
JP3
Clear CMOS
1-2 (standard)
Retains the information stored on CMOS.
2-3
Deletes the information stored on CMOS.
JP1
JP2
JP3
example)
Standard Setting (1-2)
Changing the setting (2-3)