269
PRIMERGY RX600 S3 User’s Guide
9
Op
eration
a
nd
Mainten
ance
Server Management Tools Error Messages
The following error messages may appear while executing Server Management Tools. In such cases,
perform the corresponding resolutions. If messages other than the following are displayed, contact an
office listed in the "Contact Information" of "Start Guide".
85FD
System Memory not configured
The memory configuration set in BIOS does not match
the installed memory configuration. Confirm the memory
information of each memory board using the BIOS Setup
Utility. If the message appears although the installation is
correct, replace the memory. If the message still appears,
replace the memory board. If the message still appears
after the replacement, the baseboard must be replaced.
Contact an office listed in the "Contact Information" of
"Start Guide".
table: List of Server Management Tools Error Messages
Message
Description
Write protect error writing drive A.
Abort, Retry, Fail?
The inserted floppy disk is write-protected. Disable the
write-protect, and then press the [R] key.
Not ready writing drive A.
Abort, Retry, Fail?
The floppy disk is not inserted into the floppy disk
drive. Insert the proper floppy disk ("Server
Management Tools" disk), and then press the [R] key.
Unable to open file 'xx' or file not found
The followings are possible causes. Check the floppy
disk status again.
• The floppy disk is write-protected. Disable the
write-protect and retry.
• The floppy disk is not inserted into the floppy disk
drive. Insert the proper floppy disk, and then retry.
• The floppy disk contains abnormal contents. If this
occurred while recovering BIOS information,
configure the information using the BIOS Setup
Utility. Then store the BIOS information.
• The file for recovering the BIOS information does
not exist on this floppy disk. Insert the floppy disk
on which the BIOS information was stored, and then
retry.
Unable to open 'xx'
The file 'a:\fw.scf' is not intended for this system.
The Firmware versions in the file and in the system
mismatch.
A different model or an unsupported version of BIOS/
Firmware information. Insert the proper floppy disk,
and then retry.
The file 'a:\bios.scf' is not intended for this system.
The BIOS versions in the file and in the system
mismatch.
Other messages
Refer to "Contact Information" in "Start Guide", and
contact your maintenance engineer.
table: List of POST Errors
Error
Code
Message
Description
Содержание PRIMERGY RX600 S3
Страница 44: ...44 Chapter 1 Overview ...
Страница 58: ...58 Chapter 2 Checking before OS Installation ...
Страница 136: ...136 Chapter 4 Manual OS Installation ...
Страница 180: ...180 Chapter 6 High Reliability Tools ...
Страница 292: ...292 Chapter 9 Operation and Maintenance ...
Страница 304: ...304 ...