216
Chapter 8 Operation and Maintenance
8.2.2 Error Messages
This section explains the error messages for this server.
POST error messages
When an error occurs during POST (Power On Self Test: a device check performed during the server
startup process) on this server, take the corresponding corrective actions described in the table below.
When checking/changing the settings of the BIOS Setup Utility, refer to "7.2 BIOS Setup Utility"
For instructions on checking peripheral connections, refer to "Start Guide".
For details on installing internal options, refer to "Chapter 6 Installing Internal Options" (
table: List of POST error messages
Message
Description
Failure Fixed Disk
The IDE device is abnormal. Check the "7.2.3 Standard IDE
Submenu" (
p.187) settings in the [Main] menu and the [ATA
Controller Config] settings on the "7.2.6 Peripheral
Configuration Submenu" (
p.191) in the [Advanced] menu of
the BIOS Setup Utility. If the message still appears, the
baseboard must be replaced. Contact an office listed in the
"Contact Information" of the "Start Guide".
Stuck Key
Remove objects, if any, that are pressing against any keys on the
keyboard. Check to see whether the keyboard is connected
properly and restart the system. If the message still appears, the
keyboard must be replaced.
Keyboard error
Keyboard controller error
The keyboard controller is abnormal. Replace the keyboard or
mouse. If the message still appears, the keyboard must be
replaced. Contact an office listed in the "Contact Information"
of the "Start Guide".
System RAM Failed at offset: nnnnnnnnh
The memory is abnormal. Power off the server and turn it back
on. If the message still appears, check the error log and replace
the faulty memory. If the message still appears after replacing,
the memory board or baseboard must be replaced. Contact an
office listed in the "Contact Information" of the "Start Guide".
Shadow RAM Failed at offset: nnnnnnnnh
Extended RAM Failed at address line: nnnnh
Memory type mixing detected
The installation configuration of the memory is wrong. Check
that the memory boards or memory modules are installed in the
proper slots.
Unsupported memory configuration detected
Correctable memory error in module n
The memory is abnormal. Replace the memory module that
corresponds to "module n" (where n is the slot number). If the
message still appears after replacing, the memory board or
baseboard must be replaced. Contact an office listed in the
"Contact Information" of the "Start Guide".
Uncorrectable memory error in module n
Memory decreased in Size
The memory is abnormal. Power off the server and turn it back
on. If the message still appears, check the error log and replace
the faulty memory.
Non Fujitsu Siemens Memory Module
detected Warranty restricted!
System battery is dead - Replace and run
SETUP
The battery is abnormal. Contact an office listed in the "Contact
Information" of the "Start Guide".
Содержание Primergy RX300 S4
Страница 12: ...12 ...
Страница 38: ...38 Chapter 1 Overview ...
Страница 72: ...72 Chapter 3 OS Installation ...
Страница 124: ...124 Chapter 4 Operations after OS Installation ...
Страница 132: ...132 Chapter 5 High Reliability Tools ...
Страница 180: ...180 Chapter 6 Installing Internal Options ...
Страница 266: ...266 ...