TX2560 M2 / RX2560 M2
Upgrade and Maintenance Manual
57
Basic hardware procedures
– Software / agent related errors:
Check the ServerView System Monitor, available on Windows or Linux
based servers with ServerView agents installed.
I
For further information, please refer to the "ServerView System
Monitor" user guide.
4.1.3
Locating the defective component
After determining the error class by the CSS or Global Error indicators (see
section
"Determining the error class" on page 56
), local diagnostic indicators
on the system board, HDD modules and PSUs (only slide-in units) allow you to
identify the defective component.
I
For further information, refer to the "ServerView Suite Local Service
Concept (LSC)" manual.
4.1.3.1
Local diagnostic indicators on the front
Ê
Check the CSS indicator (see section
"Onboard indicators and controls" on
) on the front panel or connector panel of the server.
I
In addition to local diagnostic indicators, CSS or Global Error LEDs
indicate, if the defective component is a customer or field replaceable
unit.
4.1.3.2
Local diagnostic indicators on the system board
Using the Indicate LDL button
Ê
Shut down and power off the server.
Ê
Disconnect the AC power cord from the system.
I
It is mandatory to disconnect power cords in order to use the Indicate
LDL functionality.
Ê
Remove the air duct as described in section
"Removing the system air duct"
Ê
Press the Indicate LDL button to highlight defective components (see
section
"Onboard indicators and controls" on page 551
)
.
Содержание PRIMERGY RX2560 M2
Страница 6: ...Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 ...
Страница 26: ...Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Contents ...
Страница 42: ...42 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Before you start ...
Страница 110: ...110 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Basic hardware procedures ...
Страница 152: ...152 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Power supply unit PSU ...
Страница 282: ...282 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Hard disk drive HDD solid state drive SSD ...
Страница 364: ...364 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Main memory ...
Страница 434: ...434 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Accessible drives ...
Страница 492: ...492 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 System board and components ...
Страница 508: ...508 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Converting a tower model to a rack model ...
Страница 544: ...544 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Cabling ...
Страница 568: ...568 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Appendix ...