TX2560 M2 / RX2560 M2
Upgrade and Maintenance Manual
287
Fans
8.2.3
Installing the new system fan module
Figure 199: Installing a system fan module
Ê
Fit the system fan module into its bay in the system fan holder as shown with
its label facing the server rear.
Ê
Gently press down on the system fan module until it locks in place.
Ê
Ensure that the connector of the system fan module properly engages with
the fan connector on the system board.
Ê
Ensure that the new system fan module spins up.
I
Please note:
When a system fan module fails, the remaining fans will start
operating at full speed. After the defective fan has been replaced, all
fans will continue to run at full speed for a couple of minutes, before
resetting to a lower speed.
Ê
Ensure that all system fan modules reset to a normal operating
speed before performing concluding steps.
Содержание PRIMERGY RX2560 M2
Страница 6: ...Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 ...
Страница 26: ...Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Contents ...
Страница 42: ...42 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Before you start ...
Страница 110: ...110 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Basic hardware procedures ...
Страница 152: ...152 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Power supply unit PSU ...
Страница 282: ...282 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Hard disk drive HDD solid state drive SSD ...
Страница 364: ...364 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Main memory ...
Страница 434: ...434 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Accessible drives ...
Страница 492: ...492 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 System board and components ...
Страница 508: ...508 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Converting a tower model to a rack model ...
Страница 544: ...544 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Cabling ...
Страница 568: ...568 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Appendix ...