382
Upgrade and Maintenance Manual
RX2540 M4
Liquid cooling (LC)
12.3 Applying the thermal paste to the CPU
surface
I
For Japan, the service engineer must follow the instruction provided
separately.
I
If the CPU upgrade or replacement kit contains a new CPU heat sink, a
thin layer of thermal compound has already been pre-applied to its lower
surface. In this case, it isn’t necessary to apply thermal paste to the CPU
surface.
Figure 264: Thermal paste syringe
One thermal compound syringe (FTS-FSP:P304000004) contains thermal
paste for three CPUs.
In order to determine the correct amount of thermal paste (equal to 1.0 gram),
divide the grey area of the syringe up into three equal segments.
I
Add graduation marks to the syringe using a permanent marker to help
you apply the thermal paste.
Содержание PRIMERGY RX2540 M4
Страница 40: ...40 Upgrade and Maintenance Manual RX2540 M4 Before you start ...
Страница 90: ...90 Upgrade and Maintenance Manual RX2540 M4 Basic hardware procedures ...
Страница 136: ...136 Upgrade and Maintenance Manual RX2540 M4 Power supply unit PSU ...
Страница 228: ...228 Upgrade and Maintenance Manual RX2540 M4 Hard disk drives HDD and solid state drives SSD ...
Страница 344: ...344 Upgrade and Maintenance Manual RX2540 M4 Main memory ...
Страница 362: ...362 Upgrade and Maintenance Manual RX2540 M4 Processor CPU ...
Страница 390: ...390 Upgrade and Maintenance Manual RX2540 M4 Liquid cooling LC ...
Страница 498: ...498 Upgrade and Maintenance Manual RX2540 M4 Additional interfaces ...
Страница 572: ...572 Upgrade and Maintenance Manual RX2540 M4 Appendix A ...
Страница 574: ...574 Upgrade and Maintenance Manual RX2540 M4 Appendix B ...
Страница 575: ...FUJITSU Server PRIMERGY RX2540 M4 System Cabling Overview System Cabling Overview English Cable plan for November 2018 ...
Страница 582: ...8 RX2540 M4 Basic Serial RS 232 Cable plan System Board D3384 RS 232 onboard RS 232 rear C6 ...
Страница 634: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan January 2017 ...