RX2540 M4
Upgrade and Maintenance Manual
109
Basic software procedures
Ê
Select
Memory Status
and verify that none of the memory modules are
marked as
Failed
.
Ê
Select
Memory Configuration
to verify
Memory Mode of Operation
.
Ê
Save your changes (if applicable) and exit the BIOS.
I
For more information on how to access the BIOS and modify settings,
see the corresponding BIOS Setup Utility reference manual.
5.2.11 Verifying the system time settings
I
This task only applies to Linux and VMware environments.
After the system board has been replaced, the system time is set automatically.
By default, the RTC (Real Time Clock) time standard is set as the local time.
If a Linux/VMware OS is used and the hardware clock has been configured as
UTC (Universal Time, Coordinated) in the operating system, the BMC local time
may not be mapped correctly.
Ê
After replacing the system board, ask the system administrator whether the
RTC or UTC time standard is to be used as system time.
I
If the system time (RTC) is set to UTC, the SEL (System Event Log)
time stamps may differ from the local time.
Ê
Enter the BIOS.
Ê
Select the
Main
menu.
Ê
Under
System Time
and
System Date
specify the correct time and date.
I
By default, the system time set in the BIOS is RTC (Real Time Clock)
local time. If your IT infrastructure relies on universally accepted time
standards, set the
System Time
to UTC (Universal Time,
Coordinated) instead. Greenwich Mean Time (GMT) can be
considered equivalent to UTC.
Ê
Save your changes and exit the BIOS.
I
For more information on how to access the BIOS and modify settings,
see the corresponding BIOS Setup Utility reference manual.
Содержание PRIMERGY RX2540 M4
Страница 40: ...40 Upgrade and Maintenance Manual RX2540 M4 Before you start ...
Страница 90: ...90 Upgrade and Maintenance Manual RX2540 M4 Basic hardware procedures ...
Страница 136: ...136 Upgrade and Maintenance Manual RX2540 M4 Power supply unit PSU ...
Страница 228: ...228 Upgrade and Maintenance Manual RX2540 M4 Hard disk drives HDD and solid state drives SSD ...
Страница 344: ...344 Upgrade and Maintenance Manual RX2540 M4 Main memory ...
Страница 362: ...362 Upgrade and Maintenance Manual RX2540 M4 Processor CPU ...
Страница 390: ...390 Upgrade and Maintenance Manual RX2540 M4 Liquid cooling LC ...
Страница 498: ...498 Upgrade and Maintenance Manual RX2540 M4 Additional interfaces ...
Страница 572: ...572 Upgrade and Maintenance Manual RX2540 M4 Appendix A ...
Страница 574: ...574 Upgrade and Maintenance Manual RX2540 M4 Appendix B ...
Страница 575: ...FUJITSU Server PRIMERGY RX2540 M4 System Cabling Overview System Cabling Overview English Cable plan for November 2018 ...
Страница 582: ...8 RX2540 M4 Basic Serial RS 232 Cable plan System Board D3384 RS 232 onboard RS 232 rear C6 ...
Страница 634: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan January 2017 ...