RX2530 M4
Upgrade and Maintenance Manual
405
System board and components
16.7.1.3 Installing the new system board
Ê
Check the settings on the new system board, see section
Ê
Insert the system board by holding it at a slight angle. Slide the connectors
into the I/O panel (see figure
Ê
Lower the system board carefully into the chassis.
Ê
Adjust the system board. If necessary adjust the position of the system
board with a gentle twisting motion (orange circles in figure
show the centering bolts).
Ê
Fasten the system board with the 12 screws (see figure
).
Ê
Fasten the four OCP bolts (see figure
Ê
For Japan / APAC / North America only:
Replace the CMOS battery installed on the new system board with a new
CMOS battery (see section
"Replacing the CMOS battery" on page 367
because charging of CMOS battery might be reduced during stocked in
warehouse.
Ê
System with air cooling:
Ê
Remove the heat sink with the CPU from the defective system board, see
section
"Removing the heat sink" on page 299
Ê
Remove the protective plastic cover from the CPU socket of the new
system board and fit it onto the socket of the defective system board
which will be sent back to spares.
I
Returned system boards without this cover probably have to be
scrapped.
Ê
Install the heat sink with the CPU on the new system board, see section
"Installing the CPU and heat sink" on page 303
.
Ê
System with liquid cooling:
Ê
Remove the protective plastic cover from the CPU socket of the new
system board and fit it onto the socket of the defective system board
which will be sent back to spares.
I
Returned system boards without this cover probably have to be
scrapped.
Содержание PRIMERGY RX2530 M4
Страница 22: ...Upgrade and Maintenance Manual RX2530 M4 Contents ...
Страница 34: ...34 Upgrade and Maintenance Manual RX2530 M4 Before you start ...
Страница 108: ...108 Upgrade and Maintenance Manual RX2530 M4 Basic software procedures ...
Страница 128: ...128 Upgrade and Maintenance Manual RX2530 M4 Power supply unit PSU ...
Страница 192: ...192 Upgrade and Maintenance Manual RX2530 M4 Hard disk drive HDD solid state drive SSD ...
Страница 200: ...200 Upgrade and Maintenance Manual RX2530 M4 Fans ...
Страница 322: ...322 Upgrade and Maintenance Manual RX2530 M4 Liquid cooling LC Figure 231 Routing the tubes Ê Run the tubes as shown ...
Страница 358: ...358 Upgrade and Maintenance Manual RX2530 M4 Front panel ...
Страница 436: ...436 Upgrade and Maintenance Manual RX2530 M4 Appendix A ...
Страница 438: ...438 Upgrade and Maintenance Manual RX2530 M4 Appendix B ...
Страница 439: ...FUJITSU Server PRIMERGY RX2530 M4 Reference Manual Reference Manual English Cable plan for September 2018 ...
Страница 465: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan January 2017 ...