Upgrade and Maintenance Manual
RX2520
M4
Basic software procedures
5.2.11 Verifying the system time settings
I
This task only applies to Linux and VMware environments.
After the system board has been replaced, the system time is set automatically.
By default, the RTC (Real Time Clock) time standard is set as the local time.
If a Linux/VMware OS is used and the hardware clock has been configured as
UTC (Universal Time, Coordinated) in the operating system, the BMC local time
may not be mapped correctly.
Ê
After replacing the system board, ask the system administrator whether the
RTC or UTC time standard is to be used as system time.
I
If the system time (RTC) is set to UTC, the SEL (System Event Log)
time stamps may differ from the local time.
Ê
Enter the BIOS.
Ê
Select the
Main
menu.
Ê
Under
System Time
and
System Date
specify the correct time and date.
I
By default, the system time set in the BIOS is RTC (Real Time Clock)
local time. If your IT infrastructure relies on universally accepted time
standards, set the
System Time
to UTC (Universal Time, Coordinated)
instead. Greenwich Mean Time (GMT) can be considered equivalent
to UTC.
Ê
Save your changes and exit the BIOS.
I
For more information on how to access the BIOS and modify settings,
see the corresponding BIOS Setup Utility reference manual.
5.2.12 Viewing and clearing the System Event Log (SEL)
5.2.12.1 Viewing the SEL
You can view the System Event Log (SEL) using the ServerView Operations
Manager or the ServerView iRMC web interface:
Viewing the SEL in ServerView Operations Manager
Ê
In ServerView Operations Manager
Single System View
select
Maintenance
from the
Information / Operation
menu.
Содержание PRIMERGY RX2520 M4
Страница 6: ...6 Upgrade and Maintenance Manual RX2520 M4 ...
Страница 22: ...Upgrade and Maintenance Manual RX2520 M4 Content ...
Страница 98: ...98 Upgrade and Maintenance Manual RX2520 M4 Basic software procedures ...
Страница 118: ...118 Upgrade and Maintenance Manual RX2520 M4 Power supply unit PSU ...
Страница 194: ...194 Upgrade and Maintenance Manual RX2520 M4 Fans ...
Страница 232: ...232 Upgrade and Maintenance Manual RX2520 M4 Expansion cards and backup units ...
Страница 310: ...310 Upgrade and Maintenance Manual RX2520 M4 Accessible drives ...
Страница 338: ...338 Upgrade and Maintenance Manual RX2520 M4 Front panel ...
Страница 346: ...346 Upgrade and Maintenance Manual RX2520 M4 Serial interface Ê Switching on the server on page 60 ...
Страница 410: ...410 Upgrade and Maintenance Manual RX2520 M4 Appendix A ...
Страница 412: ...412 Upgrade and Maintenance Manual RX2520 M4 Appendix B ...
Страница 413: ...FUJITSU Server PRIMERGY RX2520 M4 System Cabling Overview System Cabling Overview English Cable plan for June 2018 ...
Страница 451: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan January 2017 ...