RX2520 M4
Upgrade and Maintenance Manual
135
Hard disk drive (HDD) and solid state drive (SSD)
7.3.6
Removing 2.5-inch HDD/SSD modules
I
PCIe SSDs SFF are mounted in the same frames as the 2.5-inch
HDD/SSD modules. Therefore, this section is also valid and applicable if
PCIe SSDs SFF are used.
The preliminary and concluding steps are only necessary for HDD/SSD
modules, not for the PCIe SSDs SFF. PCIe SSDs SFF are never
combined in a RAID array.
7.3.6.1
Preliminary steps
Ê
If the HDD module to be removed is combined into a RAID array, please
proceed as follows:
In order to permanently remove an operational HDD module that is part of a
RAID array from the server, you first need to delete the array using
ServerView RAID Manager or BIOS Utility.
Customer Replaceable Unit
(CRU)
Hardware: 5 minutes
Tools:
tool-less
RAID level
Procedure
RAID 0
V
CAUTION!
RAID 0 provides no data redundancy.
In case of an HDD module is defect, all data
are lost!
RAID 1
RAID 5
Removing an HDD module from a RAID 1 or RAID 5
array will not result in data loss.
However, the removed drive needs to be replaced
immediately by an HDD module of the same or larger
capacity.
I
After replacing the HDD module, RAID rebuild
will be performed as a background process,
see section
"Performing a RAID array rebuild"
.
Содержание PRIMERGY RX2520 M4
Страница 6: ...6 Upgrade and Maintenance Manual RX2520 M4 ...
Страница 22: ...Upgrade and Maintenance Manual RX2520 M4 Content ...
Страница 98: ...98 Upgrade and Maintenance Manual RX2520 M4 Basic software procedures ...
Страница 118: ...118 Upgrade and Maintenance Manual RX2520 M4 Power supply unit PSU ...
Страница 194: ...194 Upgrade and Maintenance Manual RX2520 M4 Fans ...
Страница 232: ...232 Upgrade and Maintenance Manual RX2520 M4 Expansion cards and backup units ...
Страница 310: ...310 Upgrade and Maintenance Manual RX2520 M4 Accessible drives ...
Страница 338: ...338 Upgrade and Maintenance Manual RX2520 M4 Front panel ...
Страница 346: ...346 Upgrade and Maintenance Manual RX2520 M4 Serial interface Ê Switching on the server on page 60 ...
Страница 410: ...410 Upgrade and Maintenance Manual RX2520 M4 Appendix A ...
Страница 412: ...412 Upgrade and Maintenance Manual RX2520 M4 Appendix B ...
Страница 413: ...FUJITSU Server PRIMERGY RX2520 M4 System Cabling Overview System Cabling Overview English Cable plan for June 2018 ...
Страница 451: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan January 2017 ...