RX2510 M2
Operating Manual
23
Functional overview
Ambient conditions
Condensation during operation must be avoided!
Noise level
The acoustic noise values are depending on the system configuration.
Environment class 3K2
Environment class 2K2
EN 60721 / IEC 721 Part 3-3
EN 60721 / IEC 721 Part 3-2
Temperature:
Operation (3K2)
5°C ... 40°C (with Fujitsu ATD 40°C)
5°C ... 45°C (with Fujitsu ATD 45°C)
10°C ... 35°C (without Fujitsu ATD)
Transport (2K2)
-25°C ... 60°C
Humidity
10% ... 85% (non condensing)
min. configuration
1xPSU 1xCPU
max. configuration
2xPSU 2xCPU
Sound power level L
WAd
(ISO 9296)
< 4.7 B (standby)
< 4.8 B (operation)
< 5.0 B (standby)
< 5.2 B (operation)
Sound pressure level at
adjacent workstation
L
pAm
(ISO 9296)
< 31 dB(A) (standby)
< 31 dB(A) (operation)
< 34 dB(A) (standby)
< 36 dB(A) (operation)