190
Chapter 7 Configuring Hardware and Utilities
7.2.10 IPMI Submenu
This submenu appears when selecting [IPMI] from the [Advanced] menu.
Use this submenu to configure the integrated Remote Management Controller (iRMC) settings.
table: Items on the IPMI Submenu
Item
Setting
Description
SEL Load
Displays the percentage of the System Event Log (SEL) stored.
Clear System Event Log
• Disabled (Initial value)
• Enabled
Sets whether or not to delete the logs stored in the
System Event Log (SEL).
Event Log Full Mode
Overwrite (Unchangeable)
Configures the log settings when the SEL becomes
full.
iRMC Time Sync
Enabled (Unchangeable)
Sets whether or not to synchronize the internal
timer of the integrated Remote Management
Controller (iRMC) with the system time.
System Event Log
Displays the content of the SEL.
The system event logs referable in this submenu are for reference only. For details
on the system event logs, see "8.3 System Event Log" (
SDRR Browser
Displays data for each sensor.
LAN Settings
Sets the LAN when remote controlled by the RemoteControlService.
PhoenixBIOS Setup Utility
Item Specific Help
Advanced
IPMI
**%
[Disabled]
[Overwrite]
[Enabled]
SEL Load
Clear System Event Log:
Event Log Full Mode:
iRMC Time Sync:
System Event Log
SDRR Browser
LAN Settings
>
>
>
Содержание Primergy RX200 S4
Страница 12: ...12 ...
Страница 70: ...70 Chapter 3 OS Installation ...
Страница 128: ...128 Chapter 5 High Reliability Tools ...
Страница 200: ...200 Chapter 7 Configuring Hardware and Utilities ...
Страница 238: ...238 Chapter 8 Operation and Maintenance ...
Страница 264: ...264 Appendix ...
Страница 268: ...268 Numeric 3 5 inch storage bay 23 ...